Stability analysis of photovoltaic grid-connected power systems employing virtual synchronous generator control

International Journal of Power Electronics and Drive Systems · Vol. 17 No. 2 (2026) · hlm. 1451–1461

DOI
10.11591/ijpeds.v17.i2.pp1451-1461
ISSN
2722-256X, 2088-8694
Terbit
2026-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The rapid integration of photovoltaic (PV) systems into power networks poses significant challenges to grid stability, including reduced inertia, voltage fluctuations, and limited fault ride-through (FRT) capabilities. This study presents a comparative analysis of two inverter control strategies: the synchronous reference frame (SRF) controller and the virtual synchronous generator (VSG) controller. A high-fidelity MATLAB/Simulink model was developed, incorporating the effects of irradiance and temperature, maximum power point tracking (MPPT), and battery energy storage system (BESS) interaction. Standardized fault scenarios were applied at PV penetration levels ranging from 30% to 150% in accordance with IEEE-1547, IEEE-519, and IEC 61727 requirements. The results show that SRF control achieves superior harmonic suppression, with a total harmonic distortion (THD) consistently below 0.5%, confirming its suitability for strong grids prioritizing power quality. However, its stability deteriorated at higher penetration levels, with the voltage overshoot reaching approximately 16% and recovery times exceeding 3 s. In contrast, the VSG control demonstrates enhanced transient stability and effective FRT performance, with the overshoot limited to ≤5% and recovery achieved within 0.8 s across all operating conditions. The main contribution of this study lies in the direct benchmarking of the SRF and VSG control strategies under identical operating conditions using a unified evaluation framework, including an extended analysis beyond 100% PV penetration. The findings highlight a fundamental trade-off between harmonic performance and transient stability and provide practical guidance for selecting appropriate inverter control strategies for renewable-dominated power systems.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Beirut Arab University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Stability analysis of photovoltaic grid-connected power systems employing virtual synchronous generator control</dc:title>
	<dc:creator>Ghaly, Abdallah El</dc:creator>
	<dc:creator>Hamdan, Abdullah</dc:creator>
	<dc:creator>Tarnini, Mohamad</dc:creator>
	<dc:subject xml:lang="en-US">grid stability; grid-following control; grid-forming control; photovoltaic system; power quality; virtual synchronous generator synchronous reference frame</dc:subject>
	<dc:description xml:lang="en-US">The rapid integration of photovoltaic (PV) systems into power networks poses significant challenges to grid stability, including reduced inertia, voltage fluctuations, and limited fault ride-through (FRT) capabilities. This study presents a comparative analysis of two inverter control strategies: the synchronous reference frame (SRF) controller and the virtual synchronous generator (VSG) controller. A high-fidelity MATLAB/Simulink model was developed, incorporating the effects of irradiance and temperature, maximum power point tracking (MPPT), and battery energy storage system (BESS) interaction. Standardized fault scenarios were applied at PV penetration levels ranging from 30% to 150% in accordance with IEEE-1547, IEEE-519, and IEC 61727 requirements. The results show that SRF control achieves superior harmonic suppression, with a total harmonic distortion (THD) consistently below 0.5%, confirming its suitability for strong grids prioritizing power quality. However, its stability deteriorated at higher penetration levels, with the voltage overshoot reaching approximately 16% and recovery times exceeding 3 s. In contrast, the VSG control demonstrates enhanced transient stability and effective FRT performance, with the overshoot limited to ≤5% and recovery achieved within 0.8 s across all operating conditions. The main contribution of this study lies in the direct benchmarking of the SRF and VSG control strategies under identical operating conditions using a unified evaluation framework, including an extended analysis beyond 100% PV penetration. The findings highlight a fundamental trade-off between harmonic performance and transient stability and provide practical guidance for selecting appropriate inverter control strategies for renewable-dominated power systems.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24515</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v17.i2.pp1451-1461</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 17, No 2: June 2026; 1451-1461</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v17.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24515/15274</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Abdallah El Ghaly, Abdallah Hamdan, Mohamad Tarnini</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>