Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Experimental investigation of batteries thermal management system using water cooling and thermoelectric cooling techniques

International Journal of Power Electronics and Drive Systems · Vol. 15 No. 1 (2024) · hlm. 201–212

DOI
10.11591/ijpeds.v15.i1.pp201-212
ISSN
2722-256X, 2088-8694
Terbit
2024-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The booming electric vehicle industry seeks fast charging solutions to address the safety risks posed by high-power charging, including thermal runaway and other safety issues. This study investigates the impact of combining liquid with thermoelectric cooling on battery thermal management. A series of experiments were conducted using various thermal batteries, liquid flow rates and batteries temperature thermoelectric. The experimental results compared air cooling (AC), water cooling (WC), and thermoelectric cooling (TEC) with different water flow (WF) rate in system and revealed that TEC with WF at 4.0 l/min was the best cooling system. This system can decrease the temperature by about 41-52% from the maximum temperature at discharge rates of 1.0, 1.5, 2.0, 2.5, and 3.0 °C. However, TEC with WF 1.0 and 2.0 l/min can effectively lower the temperature and reduce energy consumption compared to other cooling systems, while still maintaining the battery temperature within appropriate ranges.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 8 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mahasarakham University
  • Rajamangala University of Technology Isan
  • Khon Kaen University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Taweesak ThongsanMahasarakham University2
Sakuntala NinkaewKhon Kaen University2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Experimental investigation of batteries thermal management system using water cooling and thermoelectric  cooling techniques</dc:title>
	<dc:creator>Panmuang, Piyapat</dc:creator>
	<dc:creator>Photong, Chonlatee</dc:creator>
	<dc:creator>Soemphol, Chaiyong</dc:creator>
	<dc:subject xml:lang="en-US">air cooling; BTMS; thermoelectric cooling; water cooling; water flow rate</dc:subject>
	<dc:description xml:lang="en-US">The booming electric vehicle industry seeks fast charging solutions to address the safety risks posed by high-power charging, including thermal runaway and other safety issues. This study investigates the impact of combining liquid with thermoelectric cooling on battery thermal management. A series of experiments were conducted using various thermal batteries, liquid flow rates and batteries temperature thermoelectric. The experimental results compared air cooling (AC), water cooling (WC), and thermoelectric cooling (TEC) with different water flow (WF) rate in system and revealed that TEC with WF at 4.0 l/min was the best cooling system. This system can decrease the temperature by about 41-52% from the maximum temperature at discharge rates of 1.0, 1.5, 2.0, 2.5, and 3.0 °C. However, TEC with WF 1.0 and 2.0 l/min can effectively lower the temperature and reduce energy consumption compared to other cooling systems, while still maintaining the battery temperature within appropriate ranges.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">This research project is financially supported by Faculty of Engineering, Mahasarakham University</dc:contributor>
	<dc:date>2024-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22828</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v15.i1.pp201-212</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 15, No 1: March 2024; 201-212</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v15.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22828/14416</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Chaiyong Soemphol, Piyapat Panmuang</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>