Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Comparative simulation of fractional-order PD sliding mode and fuzzy logic controllers for a second-order discrete-time nonlinear system

International Journal of Power Electronics and Drive Systems · Vol. 17 No. 3 (2026) · hlm. 1822–1830

DOI
10.11591/ijpeds.v17.i3.pp1822-1830
ISSN
2722-256X, 2088-8694
Terbit
2026-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Tight output regulation in power converters and electric drive systems requires a control strategy that simultaneously minimizes tracking error and maintains smooth actuation-two objectives that are intrinsically in tension for nonlinear, parameter-varying plants. Despite the widespread deployment of fractional-order PD sliding mode control (FOPD-SMC) and Mamdani fuzzy logic control (FLC) in this domain, no prior study has placed them in a direct, metric-identical comparison on a common plant. The present work closes this gap by implementing both controllers on the same second-order discrete-time nonlinear plant-representative of DC-DC converter output dynamics and motor-drive input-output behavior and evaluating them under a composite reference that combines sinusoidally-modulated ramps with step transitions, scored by the integral of squared error (ISE) and integral of absolute error (IAE). FOPD-SMC achieves ISE= 1.639 × 10-2 and IAE= 3.345 × 10-2, outperforming FLC by 87.6% and 50.4%, respectively; the advantage originates from the non-integer memory embedded in the sliding surface via the Gr¨unwald-Letnikov operator and from the explicit decomposition of the control law into nominal-tracking and robustness components. FLC, conversely, produces a chattering-free, continuously varying control signal a structural consequence of smooth Gaussian membership functions and linguistic rule aggregation, at the cost of a mean absolute tracking error twice that of FOPD-SMC. These findings establish a quantitative selection criterion: FOPD-SMC is recommended when tight voltage or current regulation is the primary objective, while FLC is preferred where smooth torque delivery and reduced actuator stress outweigh marginal gains in tracking accuracy.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 12 tautan kepenulisan bersama · 8 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Amar Telidji University of Laghouat
  • University Center of Aflou
  • Umm al-Qura University
  • University Yahia Fares of Medea
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohammed MekhanetAmar Telidji University of Laghouat1
Lakhdar MokraniAmar Telidji University of Laghouat1
Yacine AttiaUniversity Yahia Fares of Medea1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Comparative simulation of fractional-order PD sliding mode and fuzzy logic controllers for a second-order discrete-time nonlinear system</dc:title>
	<dc:creator>Bennaoui, Ahmed</dc:creator>
	<dc:creator>Benzian, Salah</dc:creator>
	<dc:creator>Sulimani, Hamza</dc:creator>
	<dc:creator>Ameur, Aissa</dc:creator>
	<dc:subject xml:lang="en-US">fractional-order control; Fuzzy logic control; nonlinear systems; power electronics and drive systems; sliding mode control</dc:subject>
	<dc:description xml:lang="en-US">Tight output regulation in power converters and electric drive systems requires a control strategy that simultaneously minimizes tracking error and maintains smooth actuation-two objectives that are intrinsically in tension for nonlinear, parameter-varying plants. Despite the widespread deployment of fractional-order PD sliding mode control (FOPD-SMC) and Mamdani fuzzy logic control (FLC) in this domain, no prior study has placed them in a direct, metric-identical comparison on a common plant. The present work closes this gap by implementing both controllers on the same second-order discrete-time nonlinear plant-representative of DC-DC converter output dynamics and motor-drive input-output behavior and evaluating them under a composite reference that combines sinusoidally-modulated ramps with step transitions, scored by the integral of squared error (ISE) and integral of absolute error (IAE). FOPD-SMC achieves ISE= 1.639 × 10-2 and IAE= 3.345 × 10-2, outperforming FLC by 87.6% and 50.4%, respectively; the advantage originates from the non-integer memory embedded in the sliding surface via the Gr¨unwald-Letnikov operator and from the explicit decomposition of the control law into nominal-tracking and robustness components. FLC, conversely, produces a chattering-free, continuously varying control signal a structural consequence of smooth Gaussian membership functions and linguistic rule aggregation, at the cost of a mean absolute tracking error twice that of FOPD-SMC. These findings establish a quantitative selection criterion: FOPD-SMC is recommended when tight voltage or current regulation is the primary objective, while FLC is preferred where smooth torque delivery and reduced actuator stress outweigh marginal gains in tracking accuracy.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24551</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v17.i3.pp1822-1830</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 17, No 3: September 2026; 1822-1830</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v17.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24551/15314</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Ahmed Bennaoui, Salah Benzian, Hamza Sulimani, Aissa Ameur</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>