Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Detection of single line to ground fault and self-extinguishing by using a variable and a fixedable inductance in distribution grid in power

International Journal of Power Electronics and Drive Systems · Vol. 14 No. 4 (2023) · hlm. 2044–2051

DOI
10.11591/ijpeds.v14.i4.pp2044-2051
ISSN
2722-256X, 2088-8694
Terbit
2023-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper tackled the method for determining the number of Peterson coil which is can compensate with the capacitance because it is important in determining the state of parallel resonance, which in turn control the ground fault current and make the approximate value of the current equal to the current in the sound phases. In this way, we can protect the electrical devices and equipment from being damaged by residual current resulting from the arc due to ground fault, which increases the temperature of conductors which are to a breakdown of insulators and damaging them. Ground fault current equals three times the actual current, and its effect depends on two types of variables which are the first: the number of Peterson coils (which specify the inductance value and compensated) and second: the period time of extinguishing electric are in the ground fault. we obtain, by experimental in the lab where it using the servo motor to control the number of Peterson coils which in turn specify the variable and invariable inductance. We have obtained optimal results for the value of ground-fault current, detect the ground fault and treat it without effect of network load and without power cut off for consumer.

Kata kunci

Jaringan kolaborasi para penulis

38 penulis · 106 tautan kepenulisan bersama · 48 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tun Hussein Onn University of Malaysia
  • Iraqi University
  • Shanghai Jiao Tong University
  • Al-Mustaqbal University
  • Imam Ja’afar Al-Sadiq University
  • Mehran University of Engineering & Technology Shaheed Zulfiqar Ali Bhutto Campus, Khairpur Mir's
  • Al-Furat Al-Awsat Technical University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Adnan Hasan TawafanAl-Furat Al-Awsat Technical University9
Siti Amely JumaatTun Hussein Onn University of Malaysia4
DurMuhammad SoomroAfiliasi tidak diketahui4
Sager K. AlswedTun Hussein Onn University of Malaysia4
Suriana Binti SaliminTun Hussein Onn University of Malaysia3
Mustafa Qahtan AlsudaniImam Ja’afar Al-Sadiq University3
Tahreer Safa’a MansourUniversity of Kufa2
Ahmed Hussein AlkhayyatIraqi University2
Ong Wei LiangTun Hussein Onn University of Malaysia2
Rohaiza HamdanTun Hussein Onn University of Malaysia2
Heba Abdul-Jaleel Al-AsadyIraqi University2
Lilik Jamilatul AwalinUniversitas Airlangga2
Mohamad Zhafran HussinUniversiti Teknologi MARA2
Soo Chin ChongTun Hussein Onn University of Malaysia1
Zubair Ahmed MemonTun Hussein Onn University of Malaysia1
F. AbbasiTun Hussein Onn University of Malaysia1
Muhammad Nafis IsmailTun Hussein Onn University of Malaysia1
Ahmad Fateh Mohamad NorTun Hussein Onn University of Malaysia1
Ameer Al-khaykanAl-Mustaqbal University1
Ibrahim H. Al‐KharsanIraqi University1
Ghulam Sarwar KaloiShanghai Jiao Tong University1
Jie WangShanghai Jiao Tong University1
Sohaib Tahir ChauhdaryShanghai Jiao Tong University1
Alaa Taima Albu-SalihUniversity of Al-Qadisiyah1
Hayder Ayad KhudhairAfiliasi tidak diketahui1
Syed Zahurul IslamTun Hussein Onn University of Malaysia1
Jabbar Al-Fattah YahayaTun Hussein Onn University of Malaysia1
Ummi SorfinaHitachi (Japan)1
Kok Boon ChingTun Hussein Onn University of Malaysia1
Zuraidah NgadironTun Hussein Onn University of Malaysia1
M. Y. HassanUniversity of Technology Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Detection of single line to ground fault and self-extinguishing by using a variable and a fixedable inductance in distribution grid in power</dc:title>
	<dc:creator>Jabbar, Feryal Ibrahim</dc:creator>
	<dc:creator>Soomro, Dur Muhammad</dc:creator>
	<dc:creator>Abdullah, Mohd Noor bin</dc:creator>
	<dc:creator>Radzi, Nur Hanis binti Mohammad</dc:creator>
	<dc:creator>Baloch, Mazhar Hussain</dc:creator>
	<dc:creator>Rahmoon, Asif Ahmed</dc:creator>
	<dc:creator>Fakhruldeen, Hassan Falah</dc:creator>
	<dc:subject xml:lang="en-US">distribution grid in power; distribution line; Petersen-coil; resonant grounding; servo motor</dc:subject>
	<dc:description xml:lang="en-US">This paper tackled the method for determining the number of Peterson coil which is can compensate with the capacitance because it is important in determining the state of parallel resonance, which in turn control the ground fault current and make the approximate value of the current equal to the current in the sound phases. In this way, we can protect the electrical devices and equipment from being damaged by residual current resulting from the arc due to ground fault, which increases the temperature of conductors which are to a breakdown of insulators and damaging them. Ground fault current equals three times the actual current, and its effect depends on two types of variables which are the first: the number of Peterson coils (which specify the inductance value and compensated) and second: the period time of extinguishing electric are in the ground fault. we obtain, by experimental in the lab where it using the servo motor to control the number of Peterson coils which in turn specify the variable and invariable inductance. We have obtained optimal results for the value of ground-fault current, detect the ground fault and treat it without effect of network load and without power cut off for consumer.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2023-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22576</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v14.i4.pp2044-2051</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 4: December 2023; 2044-2051</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v14.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22576/14328</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Dr. Hassan Falah Fakhruldeen</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>