Three-phase five-level CHB inverter fed induction motor for renewable applications

International Journal of Power Electronics and Drive Systems · Vol. 11 No. 3 (2020) · hlm. 1145–1152

DOI
10.11591/ijpeds.v11.i3.pp1145-1152
ISSN
2722-256X, 2088-8694
Terbit
2020-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper presents the three-phase CHB inverter fed induction motor suitable for renewable energy source applications. Normally, all present existing multilevel inverters produce multilevel output, but the number of components required is more, bulk in size, more in cost. Which are more burdens to small capacity renewable sources. These challenges are eliminated in CHB inverter. This CHB mainly consisting of one DC source, one capacitor and eight switches in each phase. To generate a five-level output in phase to ground voltage, it is required to maintain the capacitor voltage (V2) at fifty percent of the DC source voltage (V1). This capacitor voltage is regulated by a sensor less voltage regulating technique. The sensor less voltage regulation works without any sensor devices. We can implement this technique with very less cost compared to other techniques. The sensor less voltage regulation is realized by level-shifted sinusoidal pulse width modulation. The simulation results show a very good dynamic performance. Controller maintains the capacitor voltage at fifty percent of the source voltage irrespective of main source voltage changes and load changes. Inverter generates a five-level wave at the output from line to ground and seven-level wave from line to line with fewer Harmonic. It is implemented in matlab/simulink and showing good dynamic performance.

Jaringan kolaborasi para penulis

4 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Acharya Nagarjuna University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Gaddala JayarajuAcharya Nagarjuna University1
V V Nagaraju GoriparthiAcharya Nagarjuna University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Three-phase five-level CHB inverter fed induction motor for renewable applications</dc:title>
	<dc:creator>Nagaraju, G. V. V.</dc:creator>
	<dc:creator>Rao, G. Sambasiva</dc:creator>
	<dc:description xml:lang="en-US">This paper presents the three-phase CHB inverter fed induction motor suitable for renewable energy source applications. Normally, all present existing multilevel inverters produce multilevel output, but the number of components required is more, bulk in size, more in cost. Which are more burdens to small capacity renewable sources. These challenges are eliminated in CHB inverter. This CHB mainly consisting of one DC source, one capacitor and eight switches in each phase. To generate a five-level output in phase to ground voltage, it is required to maintain the capacitor voltage (V2) at fifty percent of the DC source voltage (V1). This capacitor voltage is regulated by a sensor less voltage regulating technique. The sensor less voltage regulation works without any sensor devices. We can implement this technique with very less cost compared to other techniques. The sensor less voltage regulation is realized by level-shifted sinusoidal pulse width modulation. The simulation results show a very good dynamic performance. Controller maintains the capacitor voltage at fifty percent of the source voltage irrespective of main source voltage changes and load changes. Inverter generates a five-level wave at the output from line to ground and seven-level wave from line to line with fewer Harmonic. It is implemented in matlab/simulink and showing good dynamic performance.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20511</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i3.pp1145-1152</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 3: September 2020; 1145-1152</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20511/13162</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 G. V. V. Nagaraju, G. Sambasiva Rao</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>