Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Five-level transformerless inverter with reduced voltage stress on components

International Journal of Power Electronics and Drive Systems · Vol. 15 No. 4 (2024) · hlm. 2357–2366

DOI
10.11591/ijpeds.v15.i4.pp2357-2366
ISSN
2722-256X, 2088-8694
Terbit
2024-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Leakage current flow is an important issue of transformerless (TL) inverters due to the absence of galvanic isolation between the source and grid sides in grid-connected solar photovoltaic (PV) systems. This article proposes a five-level (5L) TL direct ground point (DGP) type inverter employing two switched capacitors (SCs). The DGP configuration shares a common ground point for the PV negative terminal with grid neutral, thereby completely suppressing the leakage current. The employed semiconductors endure maximum voltage stress equivalent to the input voltage, while the switched capacitors (SCs) are rated at only half of the input voltage. This significantly reduces both the size and cost of the inverter. In addition, it uses reduced power components and has a lower total standing voltage per unit among the recent same art of topologies. A detailed comparison to show the merits of the proposed inverter is presented. Simulations and experiments were conducted at a 1 kW output power level in stand-alone as well as grid-connected mode to validate the feasibility of the proposed inverter.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Vinayaka Missions University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Five-level transformerless inverter with reduced voltage stress on components</dc:title>
	<dc:creator>Venkatesan, Rattan Kumar</dc:creator>
	<dc:creator>Lakshmikanthan, Chitra</dc:creator>
	<dc:subject xml:lang="en-US">Leakage current; multilevel inverter; self-balance; switched capacitor; transformerless inverter</dc:subject>
	<dc:description xml:lang="en-US">Leakage current flow is an important issue of transformerless (TL) inverters due to the absence of galvanic isolation between the source and grid sides in grid-connected solar photovoltaic (PV) systems. This article proposes a five-level (5L) TL direct ground point (DGP) type inverter employing two switched capacitors (SCs). The DGP configuration shares a common ground point for the PV negative terminal with grid neutral, thereby completely suppressing the leakage current. The employed semiconductors endure maximum voltage stress equivalent to the input voltage, while the switched capacitors (SCs) are rated at only half of the input voltage. This significantly reduces both the size and cost of the inverter. In addition, it uses reduced power components and has a lower total standing voltage per unit among the recent same art of topologies. A detailed comparison to show the merits of the proposed inverter is presented. Simulations and experiments were conducted at a 1 kW output power level in stand-alone as well as grid-connected mode to validate the feasibility of the proposed inverter.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23361</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v15.i4.pp2357-2366</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 15, No 4: December 2024; 2357-2366</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v15.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23361/14745</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 RATTAN KUMAR V, Chitra L</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>