Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Impacts of Photovoltaic Distributed Generation Location and Size on Distribution Power System Network

International Journal of Power Electronics and Drive Systems · Vol. 9 No. 2 (2018) · hlm. 905–913

DOI
10.11591/ijpeds.v9.i2.pp905-913
ISSN
2722-256X, 2088-8694
Terbit
2018-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

As the rapid development of photovoltaic (PV) technology in recent years with the growth of electricity demand, integration of photovoltaic distributed generation (PVDG) to the distribution system is emerging to fulfil the demand. There are benefits and drawbacks to the distribution system due to the penetration of PVDG. This paper discussed and investigated the impacts of PVDG location and size on distribution power systems. The medium voltage distribution network is connected to the grid with the load being supplied by PVDG. Load flow and short circuit calculation are analyzed by using DigSILENT Power Factory Software. Comparisons have been made between the typical distribution system and the distribution system with the penetration of PVDG. Impacts in which PVDG location and size integrates with distribution system are investigated with the results given from the load flow and short circuit analysis. The results indicate positive impacts on the system interconnected with PVDG such as improving voltage profile, reducing power losses, releasing transmission and distribution grid capacity. It also shows that optimal locations and sizes of DGs are needed to minimize the system’s power losses. On the other hand, it shows that PVDG interconnection to the system can cause reverse power flow at improper DG size and location and increases short circuit level.

Jaringan kolaborasi para penulis

19 penulis · 53 tautan kepenulisan bersama · 14 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • International Islamic University Malaysia
  • Bayero University Kano
  • Universitas Budi Luhur
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Dwi PebriantiInternational Islamic University Malaysia4
Rosdiyana SamadUniversiti Malaysia Pahang Al-Sultan Abdullah3
Mahfuzah MustafaUniversiti Malaysia Pahang Al-Sultan Abdullah3
Ibrahim Haruna ShanonoUniversiti Malaysia Pahang Al-Sultan Abdullah2
AISHA DANJUMA MUHAMMADBayero University Kano2
M. Zabri Abu BakarUniversiti Malaysia Pahang Al-Sultan Abdullah1
Khairul Amrizal Abu NawasUniversiti Malaysia Pahang Al-Sultan Abdullah1
Nurnajmin Qasrina AnnUniversiti Malaysia Pahang Al-Sultan Abdullah1
Luhur BayuajiUniversiti Malaysia Pahang Al-Sultan Abdullah1
Mohammad SyafrullahUniversitas Budi Luhur1
Siti Nor Azlina Mohd GhazaliUniversiti Malaysia Pahang Al-Sultan Abdullah1
Mahaletchumi A P MorganAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Impacts of Photovoltaic Distributed Generation Location and Size on Distribution Power System Network</dc:title>
	<dc:creator>Saad, N. Md.</dc:creator>
	<dc:creator>Sujod, M. Z.</dc:creator>
	<dc:creator>Hui Ming, Lee</dc:creator>
	<dc:creator>Abas, M. F.</dc:creator>
	<dc:creator>Jadin, M. S.</dc:creator>
	<dc:creator>Ishak, M. R.</dc:creator>
	<dc:creator>Abdullah, N. R. H.</dc:creator>
	<dc:description xml:lang="en-US">As the rapid development of photovoltaic (PV) technology in recent years with the growth of electricity demand, integration of photovoltaic distributed generation (PVDG) to the distribution system is emerging to fulfil the demand. There are benefits and drawbacks to the distribution system due to the penetration of PVDG. This paper discussed and investigated the impacts of PVDG location and size on distribution power systems. The medium voltage distribution network is connected to the grid with the load being supplied by PVDG. Load flow and short circuit calculation are analyzed by using DigSILENT Power Factory Software. Comparisons have been made between the typical distribution system and the distribution system with the penetration of PVDG. Impacts in which PVDG location and size integrates with distribution system are investigated with the results given from the load flow and short circuit analysis. The results indicate positive impacts on the system interconnected with PVDG such as improving voltage profile, reducing power losses, releasing transmission and distribution grid capacity. It also shows that optimal locations and sizes of DGs are needed to minimize the system’s power losses. On the other hand, it shows that PVDG interconnection to the system can cause reverse power flow at improper DG size and location and increases short circuit level.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/11838</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v9.i2.pp905-913</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 9, No 2: June 2018; 905-913</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v9.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/11838/11258</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 N. Md. Saad, M. Z. Sujod, Lee Hui Ming, M. F. Abas, M. S. Jadin, M. R. Ishak, N. R. H. Abdullah</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>