Abstrak

Cascaded full-bridge inverter is a suitable topology for grid-connected applications due to its ability to generate an output voltage waveform that closely resembles a sine wave, resulting in lower total harmonic distortion (THD) factors. This article proposes the use of the selective harmonic elimination (SHE) technique to produce a 5-level voltage using a symmetrical inverter and 7 and 9-level voltage using an asymmetrical inverter composed of only two full bridges loaded by an RL circuit of 51.4 Ω and 200 mH. The study primarily focuses on analysing the impact of the number of levels on the power quality of the inverter. This includes investigating the effects of the fundamental magnitude on the produced power, as well as measuring losses in the inverter, power factor, THD factor, and fundamental magnitude for each level configuration. The study demonstrates that asymmetrical MLIs lower THD (10.9% vs. 16.7%) and increasing voltage levels enhance waveform quality but slightly reduce the fundamental voltage magnitude, impacting AC power output. The simulation analysis has been conducted using the PSIM environment, and the results have been validated through experimental measurements.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 11 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sidi Mohamed Ben Abdellah University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Maha KhanfaraAfiliasi tidak diketahui2
Mohammed BoussettaAfiliasi tidak diketahui2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Performance analysis of a cascaded dual full bridges 5, 7, and 9 levels inverter: experimental validation</dc:title>
	<dc:creator>Saidani, Nabil</dc:creator>
	<dc:creator>Bachtiri, Rachid El</dc:creator>
	<dc:creator>FRI, Abdelaziz</dc:creator>
	<dc:creator>Hammoumi, Karima El</dc:creator>
	<dc:subject xml:lang="en-US">grid connected; multilevel inverter; photovoltaic; selective harmonic elimination; total harmonic distortion</dc:subject>
	<dc:description xml:lang="en-US">Cascaded full-bridge inverter is a suitable topology for grid-connected applications due to its ability to generate an output voltage waveform that closely resembles a sine wave, resulting in lower total harmonic distortion (THD) factors. This article proposes the use of the selective harmonic elimination (SHE) technique to produce a 5-level voltage using a symmetrical inverter and 7 and 9-level voltage using an asymmetrical inverter composed of only two full bridges loaded by an RL circuit of 51.4 Ω and 200 mH. The study primarily focuses on analysing the impact of the number of levels on the power quality of the inverter. This includes investigating the effects of the fundamental magnitude on the produced power, as well as measuring losses in the inverter, power factor, THD factor, and fundamental magnitude for each level configuration. The study demonstrates that asymmetrical MLIs lower THD (10.9% vs. 16.7%) and increasing voltage levels enhance waveform quality but slightly reduce the fundamental voltage magnitude, impacting AC power output. The simulation analysis has been conducted using the PSIM environment, and the results have been validated through experimental measurements.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24017</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v16.i4.pp2464-2475</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 16, No 4: December 2025; 2464-2475</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v16.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24017/15089</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Nabil Saidani, Rachid El Bachtiri, Abdelaziz FRI, Karima El Hammoumi</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>