Abstrak

Multilevel inverters have the benefit of producing high output voltage values with little distortion. This paper deals with decreasing total harmonic distortion (THD) and providing an output voltage with various step levels switching devices. In this study, a 27-level inverter with three asymmetric H-Bridge was designed and simulated based on level shift sinusoidal pulse-width modulation and phase shift sinusoidal pulse-width modulation methods. MATLAB/Simulink has been used to create this model and test it at different types of loads. The results showed that a multilevel inverter with (PS-PWM) produces less (THD) than a multilevel with (LS-PWM), when the resistive load was used, the produced voltage and current THD in (PS-PWM) and (LS-PWM) are 3.02% and 4.30% respectively, that has resulted from the linearity between voltage and current in the resistive load. While in the case of applying an inductive load, the THD in the voltage is constant in both (PS-PWM) and (LS-PWM) methods and has the same values as the THD in a resistive load. However, the THD in the current with inductive load decreased to 2.79% in (PS-PWM) and 4.04% in (LS-PWM). Finally, these results show that the performance of the proposed power circuit with PS-PWM is better than (LS-PWM).

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 5 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Ninevah University
  • Northern Technical University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Asef A. SalehNorthern Technical University1
Rakan Khalil AntarNorthern Technical University1
Noor SamiNinevah University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design and performance analysis of asymmetric multilevel inverter with reduced switches based on SPWM</dc:title>
	<dc:creator>Salman, Layth S.</dc:creator>
	<dc:creator>Al-Badrani, Harith</dc:creator>
	<dc:subject xml:lang="en-US">Asymmetric DC sources; Cascade H Bridge; Multilevel inverter; Sinusoidal pulse width modulation; Total harmonic distortion</dc:subject>
	<dc:description xml:lang="en-US">Multilevel inverters have the benefit of producing high output voltage values with little distortion. This paper deals with decreasing total harmonic distortion (THD) and providing an output voltage with various step levels switching devices. In this study, a 27-level inverter with three asymmetric H-Bridge was designed and simulated based on level shift sinusoidal pulse-width modulation and phase shift sinusoidal pulse-width modulation methods. MATLAB/Simulink has been used to create this model and test it at different types of loads. The results showed that a multilevel inverter with (PS-PWM) produces less (THD) than a multilevel with (LS-PWM), when the resistive load was used, the produced voltage and current THD in (PS-PWM) and (LS-PWM) are 3.02% and 4.30% respectively, that has resulted from the linearity between voltage and current in the resistive load. While in the case of applying an inductive load, the THD in the voltage is constant in both (PS-PWM) and (LS-PWM) methods and has the same values as the THD in a resistive load. However, the THD in the current with inductive load decreased to 2.79% in (PS-PWM) and 4.04% in (LS-PWM). Finally, these results show that the performance of the proposed power circuit with PS-PWM is better than (LS-PWM).</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2023-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21888</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v14.i1.pp320-326</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 1: March 2023; 320-326</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v14.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21888/14087</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Layth S. Salman, Harith Al-Badrani</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>