Akses terbuka
Jurnal
SINTA 1
Soft start-up strategy of pulse-density-modulated series-resonant converter for induction heating application
International Journal of Power Electronics and Drive Systems · Vol. 12 No. 1 (2021) · hlm. 258–272
ISSN 2722-256X, 2088-8694
Terbit 2021-03-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
This paper presents a soft start-up strategy of pulse-density-modulated series-resonant converter for induction heating application. The pulse-density modulation (PDM) technique is widely used in converters based on voltage-source series-resonant inverters (SRIs) to control the output current or power. However, during a start-up process, PDM has some disadvantages both in inrush current limiting and providing a zero-voltage switching operation of SRI transistors. In the paper, different PDM techniques are considered and basic moments of PDM using within the start-up process are analyzed. A new soft start-up strategy of PDM converter for induction heating application is proposed. The main features of the proposed strategy include an interleaved or a stepped PDM control, an initial combination of PDM at the beginning of the start-up process, and an operating algorithm during the start-up process. The proposed strategy was verified by a 2.5 kW experimental setup of the pulse-density-modulated interleaved converter with an operating frequency from 50 kHz up to 100 kHz. Experimental results confirm the effectiveness of the proposed start-up strategy and show that the maximum current amplitude within start-up processes exceeds the maximum steady-state current amplitude by no more than 30%.
Jaringan kolaborasi para penulis
3 penulis ·
3 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Institute of Electrodynamics
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulis Organisasi Artikel bersama
Oleg Yurchenko Institute of Electrodynamics 2
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Soft start-up strategy of pulse-density-modulated series-resonant converter for induction heating application</dc:title>
<dc:creator>Herasymenko, Pavlo</dc:creator>
<dc:creator>Pavlovskyi, Volodymyr</dc:creator>
<dc:subject xml:lang="en-US">Phase-locked loops, Pulse-density modulation, Pulse-density-modulated converter, Series-resonant inverter, Start-up strategy</dc:subject>
<dc:description xml:lang="en-US">This paper presents a soft start-up strategy of pulse-density-modulated series-resonant converter for induction heating application. The pulse-density modulation (PDM) technique is widely used in converters based on voltage-source series-resonant inverters (SRIs) to control the output current or power. However, during a start-up process, PDM has some disadvantages both in inrush current limiting and providing a zero-voltage switching operation of SRI transistors. In the paper, different PDM techniques are considered and basic moments of PDM using within the start-up process are analyzed. A new soft start-up strategy of PDM converter for induction heating application is proposed. The main features of the proposed strategy include an interleaved or a stepped PDM control, an initial combination of PDM at the beginning of the start-up process, and an operating algorithm during the start-up process. The proposed strategy was verified by a 2.5 kW experimental setup of the pulse-density-modulated interleaved converter with an operating frequency from 50 kHz up to 100 kHz. Experimental results confirm the effectiveness of the proposed start-up strategy and show that the maximum current amplitude within start-up processes exceeds the maximum steady-state current amplitude by no more than 30%.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2021-03-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20938</dc:identifier>
<dc:identifier>10.11591/ijpeds.v12.i1.pp258-272</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 1: March 2021; 258-272</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v12.i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20938/13345</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 Pavlo Herasymenko, Volodymyr Pavlovskyi</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Herasymenko, P., & Pavlovskyi, V. (2021). Soft start-up strategy of pulse-density-modulated series-resonant converter for induction heating application. International Journal of Power Electronics and Drive Systems, 12(1), 258–272. https://doi.org/10.11591/ijpeds.v12.i1.pp258-272
Salin
IEEE
P. Herasymenko and V. Pavlovskyi, “Soft start-up strategy of pulse-density-modulated series-resonant converter for induction heating application,” International Journal of Power Electronics and Drive Systems, vol. 12, no. 1, pp. 258–272, 2021, doi: 10.11591/ijpeds.v12.i1.pp258-272.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.