Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Reduction in Current THD of Grid Parallel Inverters Using Randomized PR Control

International Journal of Power Electronics and Drive Systems · Vol. 8 No. 1 (2017) · hlm. 290–296

DOI
10.11591/ijpeds.v8.i1.pp290-296
ISSN
2722-256X, 2088-8694
Terbit
2017-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In grid connected system, unity power factor current injection into the grid is vital. This can be achieved by choosing the right inverter topology, passive filter components, current controllers, and PWM switching scheme. This paper compares the output current harmonics profile between when using the conventional proportional resonant (PR) current controller and when using the modified PR current controller. By applying the latter technique, via experimental validation using TMS320F2812, the THD of the injected grid current in a parallel connected inverters system is improved.

Jaringan kolaborasi para penulis

17 penulis · 34 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tun Hussein Onn University of Malaysia
  • Newcastle University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
R. AzizTun Hussein Onn University of Malaysia4
KueiTsun ChenTun Hussein Onn University of Malaysia2
Noor Mazliza Badrul ShamTun Hussein Onn University of Malaysia1
Ronald JacksonTun Hussein Onn University of Malaysia1
M. H. RemlanTun Hussein Onn University of Malaysia1
Muhammad Shukri AhmadTun Hussein Onn University of Malaysia1
Omar Abu HassanTun Hussein Onn University of Malaysia1
Mohd Shamian ZainalTun Hussein Onn University of Malaysia1
Ahmad Alabqari Ma’radziTun Hussein Onn University of Malaysia1
Tengku Nadzlin Tengku IbrahimTun Hussein Onn University of Malaysia1
Glynn J. AtkinsonNewcastle University1
A.F.M. NoorTun Hussein Onn University of Malaysia1
Siti Amely JumaatTun Hussein Onn University of Malaysia1
Md Ruhul AminTun Hussein Onn University of Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Reduction in Current THD of Grid Parallel Inverters Using Randomized PR Control</dc:title>
	<dc:creator>Salimin, S.</dc:creator>
	<dc:creator>Zulkifli, S. A.</dc:creator>
	<dc:creator>Armstrong, M.</dc:creator>
	<dc:description xml:lang="en-US">In grid connected system, unity power factor current injection into the grid is vital. This can be achieved by choosing the right inverter topology, passive filter components, current controllers, and PWM switching scheme. This paper compares the output current harmonics profile between when using the conventional proportional resonant (PR) current controller and when using the modified PR current controller. By applying the latter technique, via experimental validation using TMS320F2812, the THD of the injected grid current in a parallel connected inverters system is improved.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2017-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6157</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i1.pp290-296</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 1: March 2017; 290-296</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6157/6006</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 S. Salimin, S. A. Zulkifli, M. Armstrong</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>