Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Control of Single Stage Grid Tied Photovoltaic Inverter Using Incremental Conductance Method

International Journal of Power Electronics and Drive Systems · Vol. 9 No. 4 (2018) · hlm. 1702–1708

DOI
10.11591/ijpeds.v9.i4.pp1702-1708
ISSN
2722-256X, 2088-8694
Terbit
2018-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In this investigation, a study on grid-connected Photovoltaic (PV) system with single stage power conversion (SSPC) is proposed. Double Stage Power Conversion (DSPC) topology contains two power conversion stages namely DC-DC conversion and DC-AC conversion, but the SSPC system converts DC power to high-quality AC power supply for grid connected PV system. The SSPC system has several advantages over DSPC, such as better use of the PV arrays, higher efficiency, low cost and compact size. Present work proposes a Sinusoidal Pulse Width Modulation (SPWM) along with incremental conductance Maximum Power Point Tracking (IC-MPPT) for inverter switching. The PV voltage and Grid Voltages verifies under normal and change of atmospheric conditions using MATLAB / SIMULINK.

Jaringan kolaborasi para penulis

13 penulis · 18 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jawaharlal Nehru Technological University Anantapur
  • Mata Gujri Memorial Medical College & Lions Seva Kendra Hospital
  • Amrita Vishwa Vidyapeetham
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
M. NayeemuddinJawaharlal Nehru Technological University Anantapur1
Teegala Bramhananda ReddyAfiliasi tidak diketahui1
D. V. Ashok KumarJawaharlal Nehru Technological University Anantapur1
K Narasimhaiah AchariJawaharlal Nehru Technological University Anantapur1
Bolla Madhusudana ReddyJawaharlal Nehru Technological University Anantapur1
Y. V. Siva ReddyAfiliasi tidak diketahui1
A Sreenivasula ReddyAfiliasi tidak diketahui1
Murali DasariJawaharlal Nehru Technological University Anantapur1
K. DeepaAmrita Vishwa Vidyapeetham1
Hridya Merin SajuAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Control of Single Stage Grid Tied Photovoltaic Inverter Using Incremental Conductance Method</dc:title>
	<dc:creator>Reddy, K. Rajasekhara</dc:creator>
	<dc:creator>Reddy, V. Nagabhaskar</dc:creator>
	<dc:creator>Kumar, M. Vijaya</dc:creator>
	<dc:description xml:lang="en-US">In this investigation, a study on grid-connected Photovoltaic (PV) system with single stage power conversion (SSPC) is proposed. Double Stage Power Conversion (DSPC) topology contains two power conversion stages namely DC-DC conversion and DC-AC conversion, but the SSPC system converts DC power to high-quality AC power supply for grid connected PV system. The SSPC system has several advantages over DSPC, such as better use of the PV arrays, higher efficiency, low cost and compact size. Present work proposes a Sinusoidal Pulse Width Modulation (SPWM) along with incremental conductance Maximum Power Point Tracking (IC-MPPT) for inverter switching. The PV voltage and Grid Voltages verifies under normal and change of atmospheric conditions using MATLAB / SIMULINK.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/12078</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v9.i4.pp1702-1708</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 9, No 4: December 2018; 1702-1708</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v9.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/12078/11475</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 K. Rajasekhara Reddy, V. Nagabhaskar Reddy, M. Vijaya Kumar</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>