Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Fuzzy Bang-Bang Control Scheme of USSC for Voltage Sag Mitigation Due to Short Circuits and Induction Motor Starting in Distribution System

International Journal of Power Electronics and Drive Systems · Vol. 4 No. 4 (2014) · hlm. 451–460

ISSN
2722-256X, 2088-8694
Terbit
2014-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Unified series shunt compensator (USSC) has been widely used to mitigate various power quality disturbances in distribution network. The USSC is almost similar to the UPFC, but the only differences are that the UPFC inverters are in shunt series connection and used in transmission systems whereas the USSC inverters are in series-shunt connection and used in distribution systems. USSC, it is possible to compensate a different power quality problem as compared to DSTATCOM and DVR. It is noted that, mitigated load voltage by the DVR is lower than mitigated value obtained by USSC. In other words the USSC can mitigate voltage sag better in compared to DVR and D-STATCOM. Also in case of voltage flicker, unbalance and harmonics elimination it is much effective. Similarly, D-STATCOM is unable to control power flow. It is seen that the proposed USSC can mitigate variety of power quality (PQ) problems. Hence due to multi capability of USSC in power quality improvement, this paper presents the scheme based on fuzzy bang-bang control for USSC. Using Fuzzy Logic Control (FLC) based on bang-bang control; the USSC will contribute to improve voltage sag without deteriorating the effect of the other compensating devices.DOI: http://dx.doi.org/10.11591/ijpeds.v4i4.6254

Jaringan kolaborasi para penulis

9 penulis · 20 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Kerman University of Medical Sciences
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Naimeh HasheminejadKerman University of Medical Sciences1
Maryam FarzadmoghadamKerman University of Medical Sciences1
Amir NekoueiKerman University of Medical Sciences1
Mohammadreza RostamizadehKerman University of Medical Sciences1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Fuzzy Bang-Bang Control Scheme of USSC for Voltage Sag Mitigation Due to Short Circuits and Induction Motor Starting in Distribution System</dc:title>
	<dc:creator>Mohammadi, Mohammad</dc:creator>
	<dc:creator>Mohammadi Rozbahani, Ashkan</dc:creator>
	<dc:creator>Abasi Garavand, Saman</dc:creator>
	<dc:creator>Montazeri, Mahdi</dc:creator>
	<dc:creator>Memarnezhad, Hamed</dc:creator>
	<dc:description xml:lang="en-US">Unified series shunt compensator (USSC) has been widely used to mitigate various power quality disturbances in distribution network. The USSC is almost similar to the UPFC, but the only differences are that the UPFC inverters are in shunt series connection and used in transmission systems whereas the USSC inverters are in series-shunt connection and used in distribution systems. USSC, it is possible to compensate a different power quality problem as compared to DSTATCOM and DVR. It is noted that, mitigated load voltage by the DVR is lower than mitigated value obtained by USSC. In other words the USSC can mitigate voltage sag better in compared to DVR and D-STATCOM. Also in case of voltage flicker, unbalance and harmonics elimination it is much effective.  Similarly, D-STATCOM is unable to control power flow.  It is seen that the proposed USSC can mitigate variety of power quality (PQ) problems. Hence due to multi capability of USSC in power quality improvement, this paper presents the scheme based on fuzzy bang-bang control for USSC. Using Fuzzy Logic Control (FLC) based on bang-bang control; the USSC will contribute to improve voltage sag without deteriorating the effect of the other compensating devices.DOI: http://dx.doi.org/10.11591/ijpeds.v4i4.6254</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2014-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5018</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 4, No 4: December 2014; 451-460</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v4.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5018/4729</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2014 Mohammad Mohammadi, Ashkan Mohammadi Rozbahani, Saman Abasi Garavand, Mahdi Montazeri, Hamed Memarnezhad</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>