Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Analysis and Impact of D-STATCOM, Static Var Compensator, Fuzzy Based SVC Controller on the Stability of a Wind Farm

International Journal of Power Electronics and Drive Systems · Vol. 8 No. 2 (2017) · hlm. 935–944

DOI
10.11591/ijpeds.v8.i2.pp935-944
ISSN
2722-256X, 2088-8694
Terbit
2017-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In recent years, applications of facts systems have been developed for the compensation of active and reactive power. Facts systems are electronics devices that are connected to the wind farm. This paper presents the impacts of some of these devices on the stability of a wind farm, especially D-STATCOM, Static Var Compensator and Fuzzy SVC controller. First, a presentation of D-STATCOM, SVC, then fuzzy logic controller. In simulation study, the D-STATCOM ensures the stability of the voltage and current at the point of connection with the electrical grid. Finally, Comparing the SVC to the F-SVC simulations, we notice that the F-SVC is more performed than SVC for the compensation of the active and reactive power.

Jaringan kolaborasi para penulis

20 penulis · 36 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mohammed V University
  • Ecole Mohammadia d'Ingénieurs
  • Université Moulay Ismail de Meknes
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Anass BakouriMohammed V University2
Marouane El AzzaouiMohammed V University2
Moine El HajjiMohammed V University1
Moussa LabbadiMohammed V University1
Naoufal ZhaniMohammed V University1
Chafik Ed-dahmaniUniversité Moulay Ismail de Meknes1
Sana SahbaniMohammed V University1
Abdennebi El HasnaouiAfiliasi tidak diketahui1
Mustapha KchikachAfiliasi tidak diketahui1
Hanane BenchraaMohammed V University1
Ilham RaisMohammed V University1
Karima BoudaraiaEcole Mohammadia d'Ingénieurs1
Ahmed AbbouMohammed V University1
Abdelaali OuhammamAfiliasi tidak diketahui1
Youssef El HachimiAfiliasi tidak diketahui1
Amina DaghouriAfiliasi tidak diketahui1
Abdennebi El HassnaouiAfiliasi tidak diketahui1
Nabil QachchachiEcole Mohammadia d'Ingénieurs1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Analysis and Impact of D-STATCOM, Static Var Compensator, Fuzzy Based SVC Controller on the Stability of a Wind Farm</dc:title>
	<dc:creator>Rabyi, Kaoutar</dc:creator>
	<dc:creator>Mahmoudi, Hassane</dc:creator>
	<dc:description xml:lang="en-US">In recent years, applications of facts systems have been developed for the compensation of active and reactive power. Facts systems are electronics devices that are connected to the wind farm. This paper presents the impacts of some of these devices on the stability of a wind farm, especially D-STATCOM, Static Var Compensator and Fuzzy SVC controller. First, a presentation of D-STATCOM, SVC, then fuzzy logic controller. In simulation study, the D-STATCOM ensures the stability of the voltage and current at the point of connection with the electrical grid. Finally, Comparing the SVC to the F-SVC simulations, we notice that the F-SVC is more performed than SVC for the compensation of the active and reactive power.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2017-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6780</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i2.pp935-944</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 2: June 2017; 935-944</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6780/6419</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Kaoutar Rabyi, Hassane Mahmoudi</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>