Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Impact of on-grid solar energy generation system on low voltage ride through capability

International Journal of Power Electronics and Drive Systems · Vol. 13 No. 1 (2022) · hlm. 488–499

DOI
10.11591/ijpeds.v13.i1.pp488-499
ISSN
2722-256X, 2088-8694
Terbit
2022-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper represented a control strategy for photovoltaic (PV) system, this control strategy was referred to as a low voltage ride through (LVRT), it had been achieved by using three phase (3-PH) (PV) grid-connected system, where this paper discussed the way to achieve maximum output active power from the solar system, while the solar system remained connected to the grid with voltage decreasing controller techniques and this was valid until certain amount of voltage decreasing which was clarified in the results. The main goal of low voltage ride through depended on injecting reactive power to the grid, amount of the injected reactive power depended on regulations of the grid code using the control of the inverter and the strategy depended on the grid voltage drop amount. MATLAB simulation had been used to achieve what was mentioned above, which led to present various cases of achieving maximum output active power with grid voltage drops by using conventional proportional integral (PI) control of the inverter. Finally, another control method, which was proportional integral genetic algorithm (PI-GA), had been used to improve value of the generated output active power.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Al-Azhar University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohammed Sh. SeifAfiliasi tidak diketahui1
Mahmoud M. ElAttarAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Impact of on-grid solar energy generation system on low voltage ride through capability</dc:title>
	<dc:creator>Shawqi, Mohammad Ahmad</dc:creator>
	<dc:creator>Abdallah, Mokhtar Hussien</dc:creator>
	<dc:creator>Nassar, Ibrahim Ahmed</dc:creator>
	<dc:subject xml:lang="en-US">genetic algorithm; grid connected; low voltage ride through; matlab simulation; solar energy generation</dc:subject>
	<dc:description xml:lang="en-US">This paper represented a control strategy for photovoltaic (PV) system, this control strategy was referred to as a low voltage ride through (LVRT), it had been achieved by using three phase (3-PH) (PV) grid-connected system, where this paper discussed the way to achieve maximum output active power from the solar system, while the solar system remained connected to the grid with voltage decreasing controller techniques and this was valid until certain amount of voltage decreasing which was clarified in the results. The main goal of low voltage ride through depended on injecting reactive power to the grid, amount of the injected reactive power depended on regulations of the grid code using the control of the inverter and the strategy depended on the grid voltage drop amount. MATLAB simulation had been used to achieve what was mentioned above, which led to present various cases of achieving maximum output active power with grid voltage drops by using conventional proportional integral (PI) control of the inverter. Finally, another control method, which was proportional integral genetic algorithm (PI-GA), had been used to improve value of the generated output active power.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2022-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21462</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v13.i1.pp488-499</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 1: March 2022; 488-499</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v13.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21462/13747</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Mohammad Ahmad Shawqi, Mokhtar Hussien Abdallah, Ibrahim Ahmed Nassar</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>