Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Modulation index effect on inverter based induction motor drive

International Journal of Power Electronics and Drive Systems · Vol. 11 No. 4 (2020) · hlm. 1785–1798

DOI
10.11591/ijpeds.v11.i4.pp1785-1798
ISSN
2722-256X, 2088-8694
Terbit
2020-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Due to a substantial increase in the use of inverter for numerous electrical appliances starting from domestics to industrial drives, an inverter may be directly connected to the power grid system. The dependency on an inverter has been increased over the years. Hence, the proper and efficient design of the inverter will lead to higher efficiency. One of the major challenges is the generation of suitable gate pulses for power switching devices, which in turn depends on the modulation index. The selection of proper modulation index will help in the production of the rated voltage. If the modulation index is less, the duration of on-time pulses will be less and hence, the device's conduction time is also less, thereby the output voltage of the inverter is reduced. A reduced voltage, when applied to an induction motor will have lower speed and even its performance will be sluggish. The speed of the motor improves when it is operated in a closed-loop for the same modulation index. This research paper tries to bring out the effect of modulation index on speed control of an induction motor based on an inverter for both open as well as closed-loop operation. The simulated results indicate that the modulation index in the vicinity to unity will provide rated voltage for the smooth operation of the motor.

Jaringan kolaborasi para penulis

8 penulis · 14 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Manipal Academy of Higher Education
  • North Eastern Regional Institute of Science and Technology
  • Thiagarajar College of Engineering
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
S. Julius FusicThiagarajar College of Engineering2
H. RameshThiagarajar College of Engineering2
V.Sai SandeepManipal Academy of Higher Education1
Pramod Antony D’saManipal Academy of Higher Education1
Mithlesh GautamManipal Academy of Higher Education1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Modulation index effect on inverter based induction motor drive</dc:title>
	<dc:creator>Sharma, Akhilesh</dc:creator>
	<dc:creator>N., Anandh</dc:creator>
	<dc:creator>Gao, Sarsing</dc:creator>
	<dc:description xml:lang="en-US">Due to a substantial increase in the use of inverter for numerous electrical appliances starting from domestics to industrial drives, an inverter may be directly connected to the power grid system. The dependency on an inverter has been increased over the years. Hence, the proper and efficient design of the inverter will lead to higher efficiency. One of the major challenges is the generation of suitable gate pulses for power switching devices, which in turn depends on the modulation index. The selection of proper modulation index will help in the production of the rated voltage. If the modulation index is less, the duration of on-time pulses will be less and hence, the device's conduction time is also less, thereby the output voltage of the inverter is reduced. A reduced voltage, when applied to an induction motor will have lower speed and even its performance will be sluggish. The speed of the motor improves when it is operated in a closed-loop for the same modulation index. This research paper tries to bring out the effect of modulation index on speed control of an induction motor based on an inverter for both open as well as closed-loop operation. The simulated results indicate that the modulation index in the vicinity to unity will provide rated voltage for the smooth operation of the motor.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20782</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i4.pp1785-1798</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 4: December 2020; 1785-1798</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20782/13257</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Akhilesh Sharma, Anandh N., Sarsing Gao</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>