Akses terbuka
Jurnal
SINTA 1
Mitigation of harmonic distortions in third rail electrical systems
International Journal of Power Electronics and Drive Systems · Vol. 14 No. 1 (2023) · hlm. 348–357
ISSN 2722-256X, 2088-8694
Terbit 2023-03-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
The extensive use of power electronic converters in the third rail system increases the harmonic distortions on the rail electrical feeding systems. Electrical machines and transformers could be overheated causing premature failures of the devices. It is therefore important to address the harmonic distortions on the electrical networks during real-time operation, which includes the degraded operation, not just the normal operation. In this paper, the harmonic distortions of a third rail system are investigated using electrical transient and analysis program (ETAP) simulation software. Four operating scenarios, namely the normal operation and three degraded operations, are considered in the studies. The degraded operations occur when one of the bulk supply transformers or 33 kV feeders is out of service. The findings of the studies showed that the 11th and 13th order harmonics are the dominant harmonic orders due to the use of 12-pulse rectifiers on the third rail system. Single-tuned harmonic filters are designed and placed in the 33 kV feeders to mitigate the individual voltage harmonic distortion (IHDv) and the total voltage harmonic distortion (THDv) so that it is within the statutory of IEEE 519:2014.
Jaringan kolaborasi para penulis
14 penulis ·
39 tautan kepenulisan bersama
· 25 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Universiti Tunku Abdul Rahman Universitas Airlangga National Cheng Kung University Universiti Malaysia Terengganu Universiti Sains Malaysia UCSI University University of Malaya
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Mitigation of harmonic distortions in third rail electrical systems</dc:title>
<dc:creator>Hoo, Dick Sang</dc:creator>
<dc:creator>Chua, Kein Huat</dc:creator>
<dc:creator>Lim, Yun Seng</dc:creator>
<dc:creator>Lim, Boon Han</dc:creator>
<dc:creator>Bonab, Mohammad Babrdel</dc:creator>
<dc:creator>Wang, Li</dc:creator>
<dc:subject xml:lang="en-US">Harmonic distortion; IEEE 519:2014; Mass rapid transit line 2; Single-tuned harmonic filter; Third rail</dc:subject>
<dc:description xml:lang="en-US">The extensive use of power electronic converters in the third rail system increases the harmonic distortions on the rail electrical feeding systems. Electrical machines and transformers could be overheated causing premature failures of the devices. It is therefore important to address the harmonic distortions on the electrical networks during real-time operation, which includes the degraded operation, not just the normal operation. In this paper, the harmonic distortions of a third rail system are investigated using electrical transient and analysis program (ETAP) simulation software. Four operating scenarios, namely the normal operation and three degraded operations, are considered in the studies. The degraded operations occur when one of the bulk supply transformers or 33 kV feeders is out of service. The findings of the studies showed that the 11th and 13th order harmonics are the dominant harmonic orders due to the use of 12-pulse rectifiers on the third rail system. Single-tuned harmonic filters are designed and placed in the 33 kV feeders to mitigate the individual voltage harmonic distortion (IHDv) and the total voltage harmonic distortion (THDv) so that it is within the statutory of IEEE 519:2014.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US">Pestech Technology Sdn Bhd</dc:contributor>
<dc:contributor xml:lang="en-US">CRSE Sdn Bhd</dc:contributor>
<dc:date>2023-03-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21894</dc:identifier>
<dc:identifier>10.11591/ijpeds.v14.i1.pp348-357</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 1: March 2023; 348-357</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v14.i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21894/14093</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2023 Dick Sang Hoo, Kein Huat Chua, Yun Seng Lim, Boon Han Lim, Mohammad Babrdel Bonab, Li Wang</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Hoo, D. S., Chua, K. H., Lim, Y. S., Lim, B. H., Bonab, M. B., & Wang, L. (2023). Mitigation of harmonic distortions in third rail electrical systems. International Journal of Power Electronics and Drive Systems, 14(1), 348–357. https://doi.org/10.11591/ijpeds.v14.i1.pp348-357
Salin
IEEE
D. S. Hoo, K. H. Chua, Y. S. Lim, B. H. Lim, M. B. Bonab, and L. Wang, “Mitigation of harmonic distortions in third rail electrical systems,” International Journal of Power Electronics and Drive Systems, vol. 14, no. 1, pp. 348–357, 2023, doi: 10.11591/ijpeds.v14.i1.pp348-357.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.