Microcontroller Based Single Phase Digital Prepaid Energy Meter for Improved Metering and Billing System

International Journal of Power Electronics and Drive Systems · Vol. 1 No. 2 (2011) · hlm. 139–147

ISSN
2722-256X, 2088-8694
Terbit
2011-11-07
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper presents a single phase digital prepaid energy meter based on two microcontrollers and a single phase energy meter IC. This digital prepaid energy meter does not have any rotating parts. The energy consumption is calculated using the output pulses of the energy meter chip and the internal counter of microcontroller (ATmega32). A microcontroller (ATtiny13) is used as a smart card and the numbers of units recharged by the consumers are written in it. A relay system has been used which either isolates or establishes the connection between the electrical load and energy meter through the supply mains depending upon the units present in the smart card.Energy consumption (kWh), maximum demand (kW), total unit recharged (kWh) and rest of the units (kWh) are stored in the ATmega32 to ensure the accurate measurement even in the event of an electrical power outage that can be easily read from a 20×4 LCD. As soon as the supply is restored, energy meter restarts with the stored values. A single phase prepaid energy meter prototype has been implemented to provide measurement up to 40A load current and 230V line to neutral voltage.Necessary program for microcontrollers are written in c-language and compiled by Win-AVR libc compiler.DOI: http://dx.doi.org/10.11591/ijpeds.v1i2.138

Jaringan kolaborasi para penulis

7 penulis · 12 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Md. Rashedul IslamAfiliasi tidak diketahui1
Md. Maruful IslamAfiliasi tidak diketahui1
Pintu Kumar SadhuAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Microcontroller Based Single Phase Digital Prepaid Energy Meter for Improved Metering and Billing System</dc:title>
	<dc:creator>Haque, Md. Mejbaul</dc:creator>
	<dc:creator>Hossain, Md. Kamal</dc:creator>
	<dc:creator>Ali, Md. Mortuza</dc:creator>
	<dc:creator>Islam Sheikh, Md. Rafiqul</dc:creator>
	<dc:description xml:lang="en-US">This paper presents a single phase digital prepaid energy meter based on two microcontrollers and a single phase energy meter IC. This digital prepaid energy meter does not have any rotating parts. The energy consumption is calculated using the output pulses of the energy meter chip and the internal counter of microcontroller (ATmega32). A microcontroller (ATtiny13) is used as a smart card and the numbers of units recharged by the consumers are written in it. A relay system has been used which either isolates or establishes the connection between the electrical load and energy meter through the supply mains depending upon the units present in the smart card.Energy consumption (kWh), maximum demand (kW), total unit recharged (kWh) and rest of the units (kWh) are stored in the ATmega32 to ensure the accurate measurement even in the event of an electrical power outage that can be easily read from a 20×4 LCD. As soon as the supply is restored, energy meter restarts with the stored values. A single phase prepaid energy meter prototype has been implemented to provide measurement up to 40A load current and 230V line to neutral voltage.Necessary program for microcontrollers are written in c-language and compiled by Win-AVR libc compiler.DOI: http://dx.doi.org/10.11591/ijpeds.v1i2.138  </dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2011-11-07</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/4872</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 1, No 2: December 2011; 139-147</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v1.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/4872/4261</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2011 Md. Mejbaul Haque, Md. Kamal Hossain, Md. Mortuza Ali, Md. Rafiqul Islam Sheikh</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>