Performance analyzes of a compact pico hydropower plant with a wide operating range

International Journal of Power Electronics and Drive Systems · Vol. 13 No. 4 (2022) · hlm. 2357–2364

DOI
10.11591/ijpeds.v13.i4.pp2357-2364
ISSN
2722-256X, 2088-8694
Terbit
2022-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper analyzes the performance of a pico hydropower plant consisting of an axial hydro turbine integrated with a permanent magnet generator (PMG) and connected to a power converter. The proposed system is aimed to obtain a wide system operation range to gain more power captured while maintaining time-harmonic distortion in voltage (THDv) that meets the standard. The PMG specification is 1 kW, 1 phase, 235 V, 50 Hz, 83 rpm. The design and simulation of PMG were carried out by analytical and numerical calculations using FEMM 4.2. The power converter was simulated using PSIM and functions to reduce the THDv and pass the generator voltage between 50–500 V. The results show the THDv of the generating system at the upper and lower limits of the passed voltage having a THDv below 5%. Meanwhile, the PMG performance characteristics at various currents and rotations produce efficiency of 87.20% at nominal current. From these results, it can be concluded that the pico hydropower plant works well as desired.

Kata kunci

Jaringan kolaborasi para penulis

37 penulis · 121 tautan kepenulisan bersama · 68 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National Research and Innovation Agency
  • Indonesian Institute of Sciences
  • Bandung Institute of Technology
  • University of Kuala Lumpur
  • Diponegoro University
  • Atma Jaya Catholic University of Indonesia
  • National University of Malaysia
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sulistyo WijanarkoNational Research and Innovation Agency10
Muhammad KasimNational Research and Innovation Agency6
Ketut WirtayasaNational Research and Innovation Agency6
Harjono Priyo SantosaNational Research and Innovation Agency3
Pekik Argo DahonoBandung Institute of Technology3
Muhammad Fathul HikmawanNational Research and Innovation Agency3
Ersalina Werda MuktiIndonesian Institute of Sciences2
Yugo KumoroIndonesian Institute of Sciences2
Yuliana SusilowatiIndonesian Institute of Sciences2
Wawan Hendriawan NurIndonesian Institute of Sciences2
Yunarto YunartoIndonesian Institute of Sciences2
Agus RisdiyantoNational Research and Innovation Agency2
Noviadi Arief RachmanIndonesian Institute of Sciences2
Bambang SusantoIndonesian Institute of Sciences2
Priyono SutiknoBandung Institute of Technology2
Qidun MaulanaIndonesian Institute of Sciences2
Budi AzhariIndonesian Institute of Sciences2
Ahmad FudholiNational University of Malaysia1
Ant. Ardath KristiNational Research and Innovation Agency1
Agus JunaediNational Research and Innovation Agency1
Indrarini Dyah IrawatiTelkom University1
Gifari Iswandi HasyimBandung Institute of Technology1
Jihad FurqaniBandung Institute of Technology1
Arwindra RizqiawanBandung Institute of Technology1
Raja Nor Firdaus Kashfi Raja OthmanUniversiti Teknikal Malaysia Melaka1
Suhairi Rizuan Che AhmadUniversity of Kuala Lumpur1
Yanawati Binti YahyaUniversity of Kuala Lumpur1
Fithri MuliawatiUniversity of Kuala Lumpur1
Qidun Maulana Binu SoesantoDiponegoro University1
Qidir Maulana Binu SoesantoDiponegoro University1
Tinton Dwi AtmajaNational Research and Innovation Agency1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Performance analyzes of a compact pico hydropower plant with a wide operating range</dc:title>
	<dc:creator>Irasari, Pudji</dc:creator>
	<dc:creator>Muqorobin, Anwar</dc:creator>
	<dc:creator>Widiyanto, Puji</dc:creator>
	<dc:creator>Nur, Tajuddin</dc:creator>
	<dc:creator>Diasta, I Nengah</dc:creator>
	<dc:creator>Soetikno, Priyono</dc:creator>
	<dc:subject xml:lang="en-US">Performance characteristics; Permanent magnet generator; Pico hydropower plant; Power converter; THDv</dc:subject>
	<dc:description xml:lang="en-US">This paper analyzes the performance of a pico hydropower plant consisting of an axial hydro turbine integrated with a permanent magnet generator (PMG) and connected to a power converter. The proposed system is aimed to obtain a wide system operation range to gain more power captured while maintaining time-harmonic distortion in voltage (THDv) that meets the standard. The PMG specification is 1 kW, 1 phase, 235 V, 50 Hz, 83 rpm. The design and simulation of PMG were carried out by analytical and numerical calculations using FEMM 4.2. The power converter was simulated using PSIM and functions to reduce the THDv and pass the generator voltage between 50–500 V. The results show the THDv of the generating system at the upper and lower limits of the passed voltage having a THDv below 5%. Meanwhile, the PMG performance characteristics at various currents and rotations produce efficiency of 87.20% at nominal current. From these results, it can be concluded that the pico hydropower plant works well as desired.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">ITB</dc:contributor>
	<dc:date>2022-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21960</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v13.i4.pp2357-2364</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 4: December 2022; 2357-2364</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v13.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21960/14030</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Pudji Irasari, Anwar Muqorobin, Puji Widiyanto, Tajuddin Nur, I Nengah Diasta, Priyono Soetikno</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>