Abstrak

When wind energy conversion systems (WECS) are integrated with the Grid system then there are power quality issues arises. The fluctuation in the wind power delivery to the grid demands robust control for a better power quality. Therefore, voltage and frequency stability due to integration of wind to the grid is the primary concern to improve the overall grid integration capability for WECS. This paper reviews the power quality issues in the power grid due to introduction of WECS. The WECS integration with the grid introduces dynamic issues that include sub-synchronous resonance (SSR), low voltage ride through (LVRT), frequency support from wind generation, synchronization, and transients. Also, it focusses on the sub synchronous resonance introduced due to introduction of doubly-fed induction generator (DFIG) wind turbines to the transmission lines with capacitive seriescompensation. The review of various power quality issues and methods used by the researcher’s mitigations are discussed and detailed further research perspective.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 5 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Vellore Institute of Technology University
  • JSPM University
  • PES University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
K. M. Mahesh KumarPES University2
Pujari Harish KumarJSPM University1
Guru Mohan BaleboinaVellore Institute of Technology University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Sub-synchronous resonance in wind energy integrated grid – problem and mitigation techniques – a review</dc:title>
	<dc:creator>Ramalingegowda, Chethan Hiremarali</dc:creator>
	<dc:creator>Rudramoorthy, Mageshvaran</dc:creator>
	<dc:subject xml:lang="en-US">Doubly fed induction generator;  Grid integration;  Series compensation; Sub synchronous resonance; Wind energy conversion system</dc:subject>
	<dc:description xml:lang="en-US">When wind energy conversion systems (WECS) are integrated with the Grid system then there are power quality issues arises. The fluctuation in the wind power delivery to the grid demands robust control for a better power quality. Therefore, voltage and frequency stability due to integration of wind to the grid is the primary concern to improve the overall grid integration capability for WECS. This paper reviews the power quality issues in the power grid due to introduction of WECS. The WECS integration with the grid introduces dynamic issues that include sub-synchronous resonance (SSR), low voltage ride through (LVRT), frequency support from wind generation, synchronization, and transients. Also, it focusses on the sub synchronous resonance introduced due to introduction of doubly-fed induction generator (DFIG) wind turbines to the transmission lines with capacitive seriescompensation. The review of various power quality issues and methods used by the researcher’s mitigations are discussed and detailed further research perspective.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2022-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21728</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v13.i3.pp1870-1886</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 3: September 2022; 1870-1886</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v13.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21728/13947</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Chethan Hiremarali Ramalingegowda, Mageshvaran Rudramoorthy</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>