Akses terbuka
Jurnal
SINTA 1
Harmonic reduction in power grids: implementing a four-legged multilevel inverter as an active power filter using model predictive control
International Journal of Power Electronics and Drive Systems · Vol. 16 No. 2 (2025) · hlm. 922–935
ISSN 2722-256X, 2088-8694
Terbit 2025-06-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
This study explores the implementation of a five-level cascaded three-phase four-wire inverter as an active power filter to mitigate harmonics in power grids. Harmonic components in the load current are transformed and filtered to create a reference current, which serves as the foundation for designing the inverter’s switching pattern. The predicted current, generated through circuit modeling, is compared with the reference current using the model predictive control (MPC) method. The accuracy of this approach is evaluated using a cost function that measures the difference between the predicted and reference currents. Simulation results reveal that the application of the hybrid power filter can effectively suppress harmonics, reducing the total harmonic distortion (THD) to below 5%, thereby meeting power quality standards. Furthermore, it addresses load imbalances, ensuring that the phase currents at the source remain nearly equal. Additionally, the hybrid power filter significantly decreases the neutral current, reducing it to just one-tenth of its original value. While MPC has demonstrated its effectiveness in controlling power converters and multilevel inverters, its application to active power filters remains underexplored. This study investigates the potential of a four-legged multilevel inverter with MPC to enhance power quality by reducing harmonics in three-phase four wire systems.
Jaringan kolaborasi para penulis
12 penulis ·
26 tautan kepenulisan bersama
· 8 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Siliwangi University Udayana University Sultan Zainal Abidin University Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Harmonic reduction in power grids: implementing a four-legged multilevel inverter as an active power filter using model predictive control</dc:title>
<dc:creator>Andang, Asep</dc:creator>
<dc:creator>Nursuwars, Firmansyah Maulana</dc:creator>
<dc:creator>Rahayu, Andri Ulus</dc:creator>
<dc:creator>Taufiqurrahman, Imam</dc:creator>
<dc:creator>Paryono, Ervan</dc:creator>
<dc:subject xml:lang="en-US">Active power filter; four-leg multilevel inverter; grid connected converter; harmonics reduction; model predictive control</dc:subject>
<dc:description xml:lang="en-US">This study explores the implementation of a five-level cascaded three-phase four-wire inverter as an active power filter to mitigate harmonics in power grids. Harmonic components in the load current are transformed and filtered to create a reference current, which serves as the foundation for designing the inverter’s switching pattern. The predicted current, generated through circuit modeling, is compared with the reference current using the model predictive control (MPC) method. The accuracy of this approach is evaluated using a cost function that measures the difference between the predicted and reference currents. Simulation results reveal that the application of the hybrid power filter can effectively suppress harmonics, reducing the total harmonic distortion (THD) to below 5%, thereby meeting power quality standards. Furthermore, it addresses load imbalances, ensuring that the phase currents at the source remain nearly equal. Additionally, the hybrid power filter significantly decreases the neutral current, reducing it to just one-tenth of its original value. While MPC has demonstrated its effectiveness in controlling power converters and multilevel inverters, its application to active power filters remains underexplored. This study investigates the potential of a four-legged multilevel inverter with MPC to enhance power quality by reducing harmonics in three-phase four wire systems.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2025-06-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23713</dc:identifier>
<dc:identifier>10.11591/ijpeds.v16.i2.pp922-935</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 16, No 2: June 2025; 922-935</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v16.i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23713/14920</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2025 Asep Andang, Firmansyah Maulana Nursuwars, Andri Ulus Rahayu, Imam Taufiqurrahman, Ervan paryono</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Andang, A., Nursuwars, F. M., Rahayu, A. U., Taufiqurrahman, I., & Paryono, E. (2025). Harmonic reduction in power grids: implementing a four-legged multilevel inverter as an active power filter using model predictive control. International Journal of Power Electronics and Drive Systems, 16(2), 922–935. https://doi.org/10.11591/ijpeds.v16.i2.pp922-935
Salin
IEEE
A. Andang, F. M. Nursuwars, A. U. Rahayu, I. Taufiqurrahman, and E. Paryono, “Harmonic reduction in power grids: implementing a four-legged multilevel inverter as an active power filter using model predictive control,” International Journal of Power Electronics and Drive Systems, vol. 16, no. 2, pp. 922–935, 2025, doi: 10.11591/ijpeds.v16.i2.pp922-935.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.