Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Fault tolerant control for DFIG wind turbine controlled by ADRC and optimized by genetic algorithm

International Journal of Power Electronics and Drive Systems · Vol. 14 No. 3 (2023) · hlm. 1382–1393

DOI
10.11591/ijpeds.v14.i3.pp1382-1393
ISSN
2722-256X, 2088-8694
Terbit
2023-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This research work deals with the modelling, control and simulation of a wind turbine based on the doubly fed induction generator (DFIG) in the current sensor’s failure event. We present in the first time the model of the wind energy conversion system based on the DFIG and the control by active disturbances rejection control (ADRC) optimized by genetic algorithm. Particular focus is directed towards on a technique for detection, identification, isolation and reconfiguration of current sensor signals after failure. The combination of the two preceding techniques makes it possible to have a fault tolerant control to sensor faults which ensures continuity of service in all circumstances. The robustness of the proposed technique is tested under the MATLAB/Simulink environment.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 32 tautan kepenulisan bersama · 8 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mohammed V University
  • Université Moulay Ismail de Meknes
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tamou NasserMohammed V University3
Issam MinkaMohammed V University2
Sara MensouMohammed V University2
Mohammed FdailiMohammed V University1
Mohamed NadourMohammed V University1
Maha AnnoukoubiMohammed V University1
Hammadi LaghridatMohammed V University1
Tammou NasserMohammed V University1
Badr Bououlid IdrissiUniversité Moulay Ismail de Meknes1
Lahssan Ben TarlaUniversité Moulay Ismail de Meknes1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Fault tolerant control for DFIG wind turbine controlled by ADRC and optimized by genetic algorithm</dc:title>
	<dc:creator>Aissaoui, Ikram</dc:creator>
	<dc:creator>Elmouhi, Noureddine</dc:creator>
	<dc:creator>Essadki, Ahmed</dc:creator>
	<dc:creator>Elaimani, Hind</dc:creator>
	<dc:subject xml:lang="en-US">ADRC; DFIG; Fault tolerant control; Genetic algorithm; Wind turbine</dc:subject>
	<dc:description xml:lang="en-US">This research work deals with the modelling, control and simulation of a wind turbine based on the doubly fed induction generator (DFIG) in the current sensor’s failure event. We present in the first time the model of the wind energy conversion system based on the DFIG and the control by active disturbances rejection control (ADRC) optimized by genetic algorithm. Particular focus is directed towards on a technique for detection, identification, isolation and reconfiguration of current sensor signals after failure. The combination of the two preceding techniques makes it possible to have a fault tolerant control to sensor faults which ensures continuity of service in all circumstances. The robustness of the proposed technique is tested under the MATLAB/Simulink environment.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Laboratory of Innovation in Management and Engineering for Enterprise (LIMIE), Institut supérieur d’ingénierie et des affaires (ISGA Rabat), 27 Avenue Oqba, Agdal, Rabat, Morocco</dc:contributor>
	<dc:date>2023-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22050</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v14.i3.pp1382-1393</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 3: September 2023; 1382-1393</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v14.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22050/14255</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Ikram Aissaoui, Noureddine Elmouhi, Ahmed Essadki, Hind Elaimani</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>