Abstrak

This paper introduces an enhanced perturb and observe (P&O) technique with a variable step size utilizing fuzzy logic to address the limitations of the traditional P&O technique, particularly under rapidly fluctuating solar radiation conditions. The performance of the suggested variable step size FLC-P&O maximum power point tracking (MPPT) and the constant step size P&O techniques is simulated and evaluated under various operating scenarios using MATLAB/Simulink software. The suggested technique was successfully validated using a boost converter connected to a Canadian Solar CS6P-240P photovoltaic (PV) model. The results demonstrate that the FLC P&O technique improves response accuracy and reduces steady-state terminal voltage fluctuations. Moreover, the findings show that the suggested technique provides a faster response and higher MPPT efficiency compared to the traditional P&O technique, particularly during sudden variations in solar irradiance.

Kata kunci

Jaringan kolaborasi para penulis

15 penulis · 41 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Hassan II Casablanca
  • Sidi Mohamed Ben Abdellah University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohamed KhafallahUniversity of Hassan II Casablanca6
Abdelmajid BerdaiUniversity of Hassan II Casablanca2
Moussa ReddakUniversity of Hassan II Casablanca2
Abdelilah HassouneUniversity of Hassan II Casablanca2
Tarik BouragbaAfiliasi tidak diketahui2
Aziz El MrabetSidi Mohamed Ben Abdellah University1
Hicham HihiSidi Mohamed Ben Abdellah University1
Mbarek ChahbounSidi Mohamed Ben Abdellah University1
Mohcine AbouyaakoubSidi Mohamed Ben Abdellah University1
Ali Ait AliSidi Mohamed Ben Abdellah University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Hybrid MPPT technique using fuzzy logic and P&amp;O of solar  power system</dc:title>
	<dc:creator>Et-Torabi, Karima</dc:creator>
	<dc:creator>Barakat, Souhail</dc:creator>
	<dc:creator>N’hili, Badr</dc:creator>
	<dc:creator>Mesbahi, Abdelouahed</dc:creator>
	<dc:creator>Nouaiti, Ayoub</dc:creator>
	<dc:subject xml:lang="en-US">DC-DC boost converter; fuzzy logic; maximum power point tracking; perturb and observe; photovoltaic</dc:subject>
	<dc:description xml:lang="en-US">This paper introduces an enhanced perturb and observe (P&amp;amp;O) technique with a variable step size utilizing fuzzy logic to address the limitations of the traditional P&amp;amp;O technique, particularly under rapidly fluctuating solar radiation conditions. The performance of the suggested variable step size FLC-P&amp;amp;O maximum power point tracking (MPPT) and the constant step size P&amp;amp;O techniques is simulated and evaluated under various operating scenarios using MATLAB/Simulink software. The suggested technique was successfully validated using a boost converter connected to a Canadian Solar CS6P-240P photovoltaic (PV) model. The results demonstrate that the FLC P&amp;amp;O technique improves response accuracy and reduces steady-state terminal voltage fluctuations. Moreover, the findings show that the suggested technique provides a faster response and higher MPPT efficiency compared to the traditional P&amp;amp;O technique, particularly during sudden variations in solar irradiance.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">ENSEM, Hassan II University</dc:contributor>
	<dc:date>2025-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24030</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v16.i2.pp1061-1069</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 16, No 2: June 2025; 1061-1069</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v16.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24030/14972</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 karima et torabi</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>