Akses terbuka
Jurnal
SINTA 1
Newly fault-tolerant indirect vector control for traction inverter
International Journal of Power Electronics and Drive Systems · Vol. 12 No. 3 (2021) · hlm. 1576–1585
ISSN 2722-256X, 2088-8694
Terbit 2021-09-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
The traction inverter is a crucial power device in the electric vehicle’s powertrain, and its failure is intolerable as it would considerably compromise the system’s safety. For more reliable driving, installing a traction inverter that is sufficiently resistant to electrical failure is inherent. Due to its compact size and the small number of switches incorporated in three-phase four-switch inverter, this modular topology was used to compensate for the open switch’s failure. However, it is known to have manifold weaknesses mainly distinguished in the low-frequency region. This paper introduces a new fault-tolerant indirect control that handles the IGBT’s failure constituting the traction inverter. The fault compensator is designed first based on the Proportional Integral regulator combined with the notch filter to mitigate the current imbalance and restore the DC voltage equilibrium.Furthermore, to conceive a comprehensive fault-tolerant control, there must therefore contain an accurate fault detector. In this regard, an uncomplicated fault diagnosis method based on the current spectral analysis has been performed. The effectiveness of the submitted controller was validated by simulation using Matlab.
Jaringan kolaborasi para penulis
19 penulis ·
49 tautan kepenulisan bersama
· 18 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Mohamed I University Université Ibn Zohr Universiti Malaysia Pahang Al-Sultan Abdullah Institut of Research in Solar Energy and New Energies Aix-Marseille Université Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Newly fault-tolerant indirect vector control for traction inverter</dc:title>
<dc:creator>Zerdani, Sara</dc:creator>
<dc:creator>Elhafyani, Mohamed Larbi</dc:creator>
<dc:creator>Fadil, Hicham</dc:creator>
<dc:creator>Zouggar, Smail</dc:creator>
<dc:subject xml:lang="en-US">Fault diagnosis; Fault-tolerant-control; Four switches inverter; IGBT’s fault; PMSM</dc:subject>
<dc:description xml:lang="en-US">The traction inverter is a crucial power device in the electric vehicle’s powertrain, and its failure is intolerable as it would considerably compromise the system’s safety. For more reliable driving, installing a traction inverter that is sufficiently resistant to electrical failure is inherent. Due to its compact size and the small number of switches incorporated in three-phase four-switch inverter, this modular topology was used to compensate for the open switch’s failure. However, it is known to have manifold weaknesses mainly distinguished in the low-frequency region. This paper introduces a new fault-tolerant indirect control that handles the IGBT’s failure constituting the traction inverter. The fault compensator is designed first based on the Proportional Integral regulator combined with the notch filter to mitigate the current imbalance and restore the DC voltage equilibrium.Furthermore, to conceive a comprehensive fault-tolerant control, there must therefore contain an accurate fault detector. In this regard, an uncomplicated fault diagnosis method based on the current spectral analysis has been performed. The effectiveness of the submitted controller was validated by simulation using Matlab.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2021-09-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21187</dc:identifier>
<dc:identifier>10.11591/ijpeds.v12.i3.pp1576-1585</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 3: September 2021; 1576-1585</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v12.i3</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21187/13551</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 Sara Zerdani, Mohamed Larbi Elhafyani, Hicham Fadil, Smail Zouggar</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Zerdani, S., Elhafyani, M. L., Fadil, H., & Zouggar, S. (2021). Newly fault-tolerant indirect vector control for traction inverter. International Journal of Power Electronics and Drive Systems, 12(3), 1576–1585. https://doi.org/10.11591/ijpeds.v12.i3.pp1576-1585
Salin
IEEE
S. Zerdani, M. L. Elhafyani, H. Fadil, and S. Zouggar, “Newly fault-tolerant indirect vector control for traction inverter,” International Journal of Power Electronics and Drive Systems, vol. 12, no. 3, pp. 1576–1585, 2021, doi: 10.11591/ijpeds.v12.i3.pp1576-1585.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.