Enhancement of Power System Stability Using Fuzzy Logic Controller

International Journal of Power Electronics and Drive Systems · Vol. 2 No. 4 (2012) · hlm. 389–401

ISSN
2722-256X, 2088-8694
Terbit
2012-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This Dissertation includes work on the development of a fuzzy logic power system stabilizer to enhance the damping of generator oscillations In order to accomplish a stability enhancement. Speed deviation (Am) and acceleration (Aw) of the rotor synchronous generator were taken as the input to the fuzzy logic controller. These variables take significant effects on damping the generator shaft mechanical oscillations. The stabilizing signals were computed using the fuzzy membership function depending on these variables. The performance of the fuzzy logic power system stabilizer was compared with the conventional power system stabilizer and without power system stabilizer. To achieve good damping characteristics over a wide range of operating conditions, speed deviation and acceleration of a synchronous machine are chosen as the input. Signal to the stabilizers. The stabilizing signal is determined from certain rules for rule-based power system stabilizer. For fuzzy logic based power system stabilizer, the supplementary stabilizing signal is determined according to the fuzzy membership function depending on the speed and acceleration states of the generator. The simulation result shows that the proposed fuzzy logic based power system stabilizer is superior to rule-based stabilizer due to its lower computation burden and robust performance.DOI: http://dx.doi.org/10.11591/ijpeds.v2i4.2127

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Enhancement of Power System Stability Using Fuzzy Logic Controller</dc:title>
	<dc:creator>Khobaragade, Tejaswita</dc:creator>
	<dc:creator>Barve, Amol</dc:creator>
	<dc:description xml:lang="en-US">This Dissertation includes work on the development of a fuzzy logic power system stabilizer to enhance the damping of generator oscillations In order to accomplish a stability enhancement. Speed deviation (Am) and acceleration (Aw) of the rotor synchronous generator were taken as the input to the fuzzy logic controller. These variables take significant effects on damping the generator shaft mechanical oscillations. The stabilizing signals were computed using the fuzzy membership function depending on these variables. The performance of the fuzzy logic power system stabilizer was compared with the conventional power system stabilizer and without power system stabilizer. To achieve good damping characteristics over a wide range of operating conditions, speed deviation and acceleration of a synchronous machine are chosen as the input. Signal to the stabilizers. The stabilizing signal is determined from certain rules for rule-based power system stabilizer. For fuzzy logic based power system stabilizer, the supplementary stabilizing signal is determined according to the fuzzy membership function depending on the speed and acceleration states of the generator. The simulation result shows that the proposed fuzzy logic based power system stabilizer is superior to rule-based stabilizer due to its lower computation burden and robust performance.DOI: http://dx.doi.org/10.11591/ijpeds.v2i4.2127</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2012-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/4918</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 2, No 4: December 2012; 389-401</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v2.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/4918/4353</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2012 Tejaswita Khobaragade, Amol Barve</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>