Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Simulation of a Transient Fault Controller for a Grid Connected Wind Farm with Different Types of Generators

International Journal of Power Electronics and Drive Systems · Vol. 1 No. 2 (2011) · hlm. 179–189

ISSN
2722-256X, 2088-8694
Terbit
2011-10-29
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper aims to simulate a wind farm model that includes wind turbine and three different types of generators, which are three-phase synchronous generator, three-phase squirrel-cage induction generator and three-phase doubly-fed induction generator,these generators are the main machines that generally used in the field of wind energy generation. All generators are connected in parallel at the point of common coupling (PCC) and connected to the utility grid. This model is a simple representation of the actual model of Zafarana, which is the biggest wind farm in Egypt and further to use it in different kinds of simulations, and display the difference in response among all generators with the same power rating (500 kW) and subjected to the same operating conditions and faults. This paper describes the simulation of the different faults that occur along the transmission line of the power system such as single-line fault, line to line fault, double lines to ground fault, and finally three line faults. The response of the wind turbine and the different generators will be analyzed and discussed to compare the transient response of all generators at the different types of faults, where the fault period is selected to be 300 ms. The model is created in MATLAB software that enables the dynamic and static simulations of electric, electromagnetic and electromechanical systems. The machines are standard blocks in the software library.Keywords: transient faults, wind farm, simulation model.DOI: http://dx.doi.org/10.11591/ijpeds.v1i2.104

Jaringan kolaborasi para penulis

7 penulis · 10 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Helwan University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
S. A. GawishAfiliasi tidak diketahui1
M. S. El-HaronyAfiliasi tidak diketahui1
Helmy Mohammed El_ ZoghbyAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Simulation of a Transient Fault Controller for a Grid Connected Wind Farm with Different Types of Generators</dc:title>
	<dc:creator>Abdel-Mageed, Helmy Mohammed</dc:creator>
	<dc:creator>Sharaf, S.M.</dc:creator>
	<dc:creator>El_masry, S.M.</dc:creator>
	<dc:creator>El_harony, M.</dc:creator>
	<dc:description xml:lang="en-US">This paper aims to simulate a wind farm model that includes wind turbine and three different  types of generators , which are three-phase synchronous generator, three-phase squirrel-cage induction generator and three-phase doubly-fed induction generator ,these generators are the main machines that generally used in the field of wind energy generation. All generators are connected in parallel at the point of common coupling (PCC) and connected to the utility grid.  This model is a simple representation of the actual model of  Zafarana,  which is the biggest wind farm in Egypt and further to use it in different kinds of simulations, and display the difference in response among all generators with the same power rating (500 kW) and subjected to the same operating conditions and faults. This paper describes the simulation of the different faults that occur along the transmission line of the power system such as single-line fault, line to line fault, double lines to ground fault, and finally three line faults. The response of the wind turbine and the different generators will be analyzed and discussed to compare the transient response of all generators at the different types of faults, where the fault period is selected to be 300 ms. The model is created in MATLAB software that enables the dynamic and static simulations of electric, electromagnetic and electromechanical systems. The machines are standard blocks in the software library.Keywords: transient faults, wind farm, simulation model.DOI: http://dx.doi.org/10.11591/ijpeds.v1i2.104</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2011-10-29</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/4877</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 1, No 2: December 2011; 179-189</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v1.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/4877/4266</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2011 Helmy Mohammed Abdel-Mageed, S.M. Sharaf, S.M. El_masry, M. El_harony</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>