Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Improved dead-time elimination method for three-phase power inverters

International Journal of Power Electronics and Drive Systems · Vol. 11 No. 4 (2020) · hlm. 1759–1766

DOI
10.11591/ijpeds.v11.i4.pp1759-1766
ISSN
2722-256X, 2088-8694
Terbit
2020-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In real inverters' operations, it is essential to insert delay time in the pulses provided to the inverter switches to protect the DC link against the short circuits. From this situation, the dead time phenomenon is introduced that causes undesirable performance and distortion of the output signal. Previously, researchers have proposed various schemes for compensating or eliminating dead-time. In this paper, a new dead-time elimination (DTE) scheme is proposed with a guarantee algorithm to eliminate dead-time and overcome the issues produced at the zero-currents-crossing point (ZCC). This method does not require additional hardware or filters to determine the polarity of the output current, and its principle is very simple to implement. The developed DTE method completely removes the dead-time issues on the magnitude and phase of the output voltage, and avoid the problems which can be induced around the ZCC. The results confirm the effectiveness and safety of this method.

Jaringan kolaborasi para penulis

18 penulis · 79 tautan kepenulisan bersama · 45 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Al-Quds University
  • University of Eloued
  • Tomsk Polytechnic University
  • Zagazig University
  • Novosibirsk State Technical University
  • Ahmed Draia University
  • Larbi Ben M'hidi University of Oum El Bouaghi
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Djaafar ToumiAl-Quds University5
Sergey ObukhovTomsk Polytechnic University4
Ahfouda AbdelkarimAl-Quds University3
Youcef BekakraAl-Quds University3
Laid ZelloumaAl-Quds University3
Messaoud ZobeidiUniversity of Eloued2
Djilani BenattousUniversity of Eloued2
Hicham SerhoudUniversity of Eloued2
Bedida TarekAhmed Draia University2
Fethi KhelaifaLarbi Ben M'hidi University of Oum El Bouaghi2
Yacine LabbiAl-Quds University2
Mohamed Tayeb BoussabeurAl-Quds University2
A. IbrahimAfiliasi tidak diketahui2
Hettiri MessaoudAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Improved dead-time elimination method for three-phase power inverters</dc:title>
	<dc:creator>Aboelsaud, Raef</dc:creator>
	<dc:creator>Ibrahim, Ahmed</dc:creator>
	<dc:creator>Garganeev, Alexander G.</dc:creator>
	<dc:creator>Aleksandrov, Ivan V.</dc:creator>
	<dc:description xml:lang="en-US">In real inverters' operations, it is essential to insert delay time in the pulses provided to the inverter switches to protect the DC link against the short circuits. From this situation, the dead time phenomenon is introduced that causes undesirable performance and distortion of the output signal. Previously, researchers have proposed various schemes for compensating or eliminating dead-time. In this paper, a new dead-time elimination (DTE) scheme is proposed with a guarantee algorithm to eliminate dead-time and overcome the issues produced at the zero-currents-crossing point (ZCC). This method does not require additional hardware or filters to determine the polarity of the output current, and its principle is very simple to implement. The developed DTE method completely removes the dead-time issues on the magnitude and phase of the output voltage, and avoid the problems which can be induced around the ZCC. The results confirm the effectiveness and safety of this method.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/15880</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i4.pp1759-1766</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 4: December 2020; 1759-1766</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/15880/13254</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Raef Aboelsaud, Ahmed Ibrahim, Alexander G. Garganeev, Ivan V. Aleksandrov</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>