Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

A New Structure of the Nine Level Inverter Used as Active Power Filter with a Reduced Number of Swiches

International Journal of Power Electronics and Drive Systems · Vol. 9 No. 1 (2018) · hlm. 198–209

DOI
10.11591/ijpeds.v9.i1.pp198-209
ISSN
2722-256X, 2088-8694
Terbit
2018-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In the scope of this work, a new structure of the nine level inverter is proposed using a reduced number of power switches. This inverter is used as a shunt active power filter to compensate harmonic currents and the reactive power. The modeling and simulation of the proposed model were carried out in Matlab/Simulink environment. The simulation results show that the filtering performances were achieved despite the reduction of the switches number. It was found that the current waveform becomes purely sinusoidal with a reduction in the harmonic distortion rate (THD) to 2.68%. This implies good compensation of both harmonics and reactive power with a power factor closer to unity. Reducing the switches number allows reducing the switching losses and lowering the duration of the applied voltage supported by the semiconductors. The proposed topology also allows to get simple structure of the inverter with a reduced cost.

Jaringan kolaborasi para penulis

6 penulis · 8 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Badji Mokhtar-Annaba University
  • Mohamed-Cherif Messaadia University
  • University Mohamed Boudiaf of M'sila
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Saida DahmaneUniversity Mohamed Boudiaf of M'sila1
Fouad BerrabahBadji Mokhtar-Annaba University1
Mabrouk DefdafBadji Mokhtar-Annaba University1
Abdelmalik BendaikhaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">A New Structure of the Nine Level Inverter Used as Active Power Filter with a Reduced Number of Swiches</dc:title>
	<dc:creator>Chouaf, Fethi</dc:creator>
	<dc:creator>Saad, Salah</dc:creator>
	<dc:description xml:lang="en-US">In the scope of this work, a new structure of the nine level inverter is proposed using a reduced number of power switches. This inverter is used as a shunt active power filter to compensate harmonic currents and the reactive power. The modeling and simulation of the proposed model were carried out in Matlab/Simulink environment. The simulation results show that the filtering performances were achieved despite the reduction of the switches number. It was found that the current waveform becomes purely sinusoidal with a reduction in the harmonic distortion rate (THD) to 2.68%. This implies good compensation of both harmonics and reactive power with a power factor closer to unity. Reducing the switches number allows reducing the switching losses and lowering the duration of the applied voltage supported by the semiconductors. The proposed topology also allows to get simple structure of the inverter with a reduced cost.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/9038</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v9.i1.pp198-209</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 9, No 1: March 2018; 198-209</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v9.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/9038/11125</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 Fethi Chouaf, Salah Saad</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>