Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Experimental Prototype Model of IDVR for Bidirectional Voltage Compensation

International Journal of Power Electronics and Drive Systems · Vol. 9 No. 1 (2018) · hlm. 297–304

DOI
10.11591/ijpeds.v9.i1.pp297-304
ISSN
2722-256X, 2088-8694
Terbit
2018-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Interline Dynamic Voltage Restorer (IDVR) is an optimum solution to compensate voltage sag in multiple lines. The IDVR consisting of two or more DVRs connected to different feeders in a power system sharing a common DC link energy. This paper presents the hardware implementation of novel bidirectional voltage sag compensation by the IDVR in multiple feeders at same instance. A two line feeder power system with IDVR installed is considered. The IDVR is implemented using two VSI with filter. The control system of IDVR is developed using DSPACE 1103.

Jaringan kolaborasi para penulis

20 penulis · 62 tautan kepenulisan bersama · 22 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Koneru Lakshmaiah Education Foundation
  • Birla Institute of Technology and Science - Hyderabad Campus
  • Jawaharlal Nehru Technological University, Hyderabad
  • R.V. College of Engineering
  • PES University
  • B.M.S. College of Engineering
  • Birla Institute of Technology and Science, Pilani
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
A. V. Pavan KumarAfiliasi tidak diketahui2
Abha TripathiPES University1
L. VenkateshaB.M.S. College of Engineering1
B. JyothiKoneru Lakshmaiah Education Foundation1
Malligunta Kiran KumarKoneru Lakshmaiah Education Foundation1
Rakesh TeerdalaJawaharlal Nehru Technological University, Hyderabad1
Kambhampati Venkata Govardhan RaoKoneru Lakshmaiah Education Foundation1
N. KeerthiKoneru Lakshmaiah Education Foundation1
M. SharanyaAfiliasi tidak diketahui1
CH. SrinivasJawaharlal Nehru Technological University, Hyderabad1
K. ShravaniAfiliasi tidak diketahui1
V. Sanjeeva RaoAfiliasi tidak diketahui1
Sridhar Babu GurijalaKoneru Lakshmaiah Education Foundation1
Keshavmurthy Subramanian SrikanthKoneru Lakshmaiah Education Foundation1
G. Rohit ReddyAfiliasi tidak diketahui1
Vishnu Charan ThippanaAfiliasi tidak diketahui1
Karri ChandramBirla Institute of Technology and Science, Pilani1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Experimental Prototype Model of IDVR for Bidirectional Voltage Compensation</dc:title>
	<dc:creator>Nittala, Ramchandra</dc:creator>
	<dc:creator>Parimi, Alivelu M.</dc:creator>
	<dc:creator>Rao, K. Uma</dc:creator>
	<dc:description xml:lang="en-US">Interline Dynamic Voltage Restorer (IDVR) is an optimum solution to compensate voltage sag in multiple lines. The IDVR consisting of two or more DVRs connected to different feeders in a power system sharing a common DC link energy. This paper presents the hardware implementation of novel bidirectional voltage sag compensation by the IDVR in multiple feeders at same instance.  A two line feeder power system with IDVR installed is considered. The IDVR is implemented using two VSI with filter. The control system of IDVR is developed using DSPACE 1103. </dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/9301</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v9.i1.pp297-304</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 9, No 1: March 2018; 297-304</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v9.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/9301/11134</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 Ramchandra Nittala, Alivelu M. Parimi, K. Uma Rao</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>