Abstrak

This paper provides a new approach to reducing high-order harmonics in 400 Hz inverter using a three-level neutral-point clamped (NPC) converter. A voltage control loop using the harmonic compensation combined with NPC clamping diode control technology. The capacitor voltage imbalance also causes harmonics in the output voltage. For 400 Hz inverter, maintain a balanced voltage between the two input (direct current) (DC) capacitors is difficult because the pulse width modulation (PWM) modulation frequency ratio is low compared to the frequency of the output voltage. A method of determining the current flowing into the capacitor to control the voltage on the two balanced capacitors to ensure fast response reversal is also given in this paper. The combination of a high-harmonic resonator controller and a neutral-point voltage controller working together on the 400 Hz NPC inverter structure is given in this paper.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 26 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Hanoi University of Science and Technology
  • Electric Power University
  • Thai Nguyen University of Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nguyễn Thị DiệpElectric Power University4
Trần Trọng MinhHanoi University of Science and Technology2
Phuong Viet PhamHanoi University of Science and Technology1
H ThốngHanoi University of Science and Technology1
Nguyen Hoang LinhHanoi University of Science and Technology1
Hoang Van CanhHanoi University of Science and Technology1
Diep Huynh VanHanoi University of Science and Technology1
Son Tran QueThai Nguyen University of Technology1
Vuong Nguyen AnhHanoi University of Science and Technology1
Quang Dich NguyenHanoi University of Science and Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The new approach minimizes harmonics in a single-phase three-level NPC 400 Hz converter for airplanes</dc:title>
	<dc:creator>Quy, Do Ngoc</dc:creator>
	<dc:creator>Ba Phu, Do</dc:creator>
	<dc:creator>Kien Trung, Nguyen</dc:creator>
	<dc:subject xml:lang="en-US">400 Hz inverter; Balance neutral point; Minimize harmonics; NPC</dc:subject>
	<dc:description xml:lang="en-US">This paper provides a new approach to reducing high-order harmonics in 400 Hz inverter using a three-level neutral-point clamped (NPC) converter. A voltage control loop using the harmonic compensation combined with NPC clamping diode control technology. The capacitor voltage imbalance also causes harmonics in the output voltage. For 400 Hz inverter, maintain a balanced voltage between the two input (direct current) (DC) capacitors is difficult because the pulse width modulation (PWM) modulation frequency ratio is low compared to the frequency of the output voltage. A method of determining the current flowing into the capacitor to control the voltage on the two balanced capacitors to ensure fast response reversal is also given in this paper. The combination of a high-harmonic resonator controller and a neutral-point voltage controller working together on the 400 Hz NPC inverter structure is given in this paper.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">This research is funded by the Hanoi University of Science and Technology (HUST) under project number DTDL.CN-14/18.</dc:contributor>
	<dc:date>2021-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21008</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v12.i3.pp1738-1750</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 3: September 2021; 1738-1750</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v12.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21008/13515</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Do Ngoc Quy, Do Ba Phu, Nguyen Kien Trung</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>