Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Steady state stability assessment of voltage source converter in a DC microgrid under weak grid conditions

International Journal of Power Electronics and Drive Systems · Vol. 15 No. 2 (2024) · hlm. 802–814

DOI
10.11591/ijpeds.v15.i2.pp802-814
ISSN
2722-256X, 2088-8694
Terbit
2024-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Traditionally, steady-state assessment involves analyzing numerous variables using Eigen analysis. This paper presents a decision support application for diagnosing the steady-state assessment of droop-controlled voltage source inverters in islanded microgrid operations or weak grid operations with reduced input attributes. This paper proposes an approach using feature extraction from the state space variables of the droop-controlled voltage source inverter (VSI). Photovoltaic (PV) and wind energy sources are considered with their stipulated power-delivering capability considered. To improve the generalization of the predictive model, preprocessing techniques are employed to eliminate data distortions. Dimensionality reduction is achieved through principal component analysis (PCA) applied to the steady-state variables. The evaluation of the VSI's steady-state stability is conducted utilizing support vector classification algorithm. To ascertain the reliability of the steady-state stability classification, an assessment of the support vector machine (SVM) model's performance is carried out, which includes the examination of metrics like the area under the curve (AUC) and the receiver operating characteristics (ROC) curve. The findings from the assessment of VSI's steady-state stability indicate a commendable level of performance, achieving an accuracy rate of 93.5%.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 2 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohankumar VenugopalAfiliasi tidak diketahui2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Steady state stability assessment of voltage source converter in a DC microgrid under weak grid conditions</dc:title>
	<dc:creator>Viswanathan, Ganeshan</dc:creator>
	<dc:creator>Jayaramaiah, Govindanayakanapalya Venkatagiriyappa</dc:creator>
	<dc:subject xml:lang="en-US">droop controller; islanded microgrid; steady-state stability assessment; support vector machine; voltage source inverters</dc:subject>
	<dc:description xml:lang="en-US">Traditionally, steady-state assessment involves analyzing numerous variables using Eigen analysis. This paper presents a decision support application for diagnosing the steady-state assessment of droop-controlled voltage source inverters in islanded microgrid operations or weak grid operations with reduced input attributes. This paper proposes an approach using feature extraction from the state space variables of the droop-controlled voltage source inverter (VSI). Photovoltaic (PV) and wind energy sources are considered with their stipulated power-delivering capability considered. To improve the generalization of the predictive model, preprocessing techniques are employed to eliminate data distortions. Dimensionality reduction is achieved through principal component analysis (PCA) applied to the steady-state variables. The evaluation of the VSI's steady-state stability is conducted utilizing support vector classification algorithm. To ascertain the reliability of the steady-state stability classification, an assessment of the support vector machine (SVM) model's performance is carried out, which includes the examination of metrics like the area under the curve (AUC) and the receiver operating characteristics (ROC) curve. The findings from the assessment of VSI's steady-state stability indicate a commendable level of performance, achieving an accuracy rate of 93.5%.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22876</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v15.i2.pp802-814</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 15, No 2: June 2024; 802-814</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v15.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22876/14561</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Ganeshan Viswanathan</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>