The study is aimed to determine the measurement of sensor tool made in Model Real Time Hybrid LFG-PV-Genset by finding the correction factor produced at TPA Bontang City, East Borneo. The research was conducted by using ampere clammeter, variable voltage regulator, thermometer, odalog7000 series. The calculation results show that the calibration test of Model Real Time Hybrid LFG-PV-Genset from MQ4 sensor data that has been designed capable of having errors of 1,91% and the LM35 temperature sensor is capable of monitoring tempertures of 30°C to 120°C and has an error value of 0,519°C. ZMPT 101B voltage sensor has a linear output change to input changes and has an average error of 1.499V. While the current sensor SCT 013 has an aerage error value of 0,0022A CO2.

Jaringan kolaborasi para penulis

5 penulis · 7 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Hasanuddin University
  • Universitas DIPA Makassar
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sadly SyamsuddinUniversitas DIPA Makassar1
Ady Wahyudi PaunduHasanuddin University1
Muhammad Bachtiar NappuHasanuddin University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The Calibration Test Of Hybrid Landfill Gas -Photovoltaic-Genset Model In Bontang, East Borneo</dc:title>
	<dc:creator>Manjang, Salama</dc:creator>
	<dc:creator>Ahsan, Sitti Hamnah</dc:creator>
	<dc:description xml:lang="en-US">The study is aimed to determine the measurement of sensor tool made in Model Real Time Hybrid LFG-PV-Genset by finding the correction factor produced at TPA Bontang City, East Borneo. The research was conducted by using ampere clammeter, variable voltage regulator, thermometer, odalog7000 series.  The calculation results  show that the calibration test of Model Real Time Hybrid LFG-PV-Genset from MQ4 sensor data that has been designed capable of having errors of 1,91% and the LM35 temperature sensor is capable of monitoring tempertures of 30°C to 120°C and has an error value of 0,519°C. ZMPT 101B voltage sensor has a linear output change to input changes and has an average error of 1.499V. While the current sensor SCT 013 has an aerage error value of 0,0022A CO2.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Sitti Hamnah Ahsan, Universitas Hasanuddin, Doctoral of Student, Department of Electrical Engineering</dc:contributor>
	<dc:date>2018-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/9105</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v9.i1.pp89-97</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 9, No 1: March 2018; 89-97</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v9.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/9105/11114</dc:relation>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/downloadSuppFile/9105/822</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 Salama Manjang, Sitti Hamnah Ahsan</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>