Performance analysis of LMS based control algorithm for power quality improvement in three phase grid connected system for linear/non-linear load

International Journal of Power Electronics and Drive Systems · Vol. 10 No. 4 (2019) · hlm. 1944–1950

DOI
10.11591/ijpeds.v10.i4.pp1944-1950
ISSN
2722-256X, 2088-8694
Terbit
2019-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper presents the adaptive filtering based least mean square control algorithm for distribution static compensator (DSTATCOM) in three-phase grid tied system for linear/non-linear load, to solve the power quality problems caused by solid-state equipment and devices. This is shown that the active component weights obtained from the load currents in the LMS adaptive filter are used to produce the reference currents and subsequently produces the switching pulses for VSC of the compensator. The complete circuit along with the adaptive technique and diode bridge rectifier type nonlinear load is simulated in Matlab/Simulink software. Initially the circuit was simulated for a three phase linear inductive load. Later it was simulated for a rectifier load connected at PCC with a disconnection of the load of any phase for a short duration of time. It is concluded that the harmonics are found within the limit. The harmonics and power results for both types of loads are compared in a tabular form. Hence this three phase system with DSTATCOM improves the power quality in the three-phase distribution network therefore, serves to provide harmonics reduction, load balancing and regulating the terminal voltage at the point of common coupling (PCC).

Jaringan kolaborasi para penulis

6 penulis · 11 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Aligarh Muslim University
  • Jamia Millia Islamia
  • National Taiwan University of Science and Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Khan MohammadAligarh Muslim University1
Shoeb Azam FarooquiNational Taiwan University of Science and Technology1
Wajid AliAligarh Muslim University1
Farha KhanAligarh Muslim University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Performance analysis of LMS based control algorithm for power quality improvement in three phase grid connected system for linear/non-linear load</dc:title>
	<dc:creator>Ahmad, Mohmmad</dc:creator>
	<dc:creator>Kirmani, Sheeraz</dc:creator>
	<dc:subject xml:lang="en-US"></dc:subject>
	<dc:description xml:lang="en-US">This paper presents the adaptive filtering based least mean square control algorithm for distribution static compensator (DSTATCOM) in three-phase grid tied system for linear/non-linear load, to solve the power quality problems caused by solid-state equipment and devices. This is shown that the active component weights obtained from the load currents in the LMS adaptive filter are used to produce the reference currents and subsequently produces the switching pulses for VSC of the compensator. The complete circuit along with the adaptive technique and diode bridge rectifier type nonlinear load is simulated in Matlab/Simulink software. Initially the circuit was simulated for a three phase linear inductive load. Later it was simulated for a rectifier load connected at PCC with a disconnection of the load of any phase for a short duration of time. It is concluded that the harmonics are found within the limit. The harmonics and power results for both types of loads are compared in a tabular form. Hence this three phase system with DSTATCOM improves the power quality in the three-phase distribution network therefore, serves to provide harmonics reduction, load balancing and regulating the terminal voltage at the point of common coupling (PCC).</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2019-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/18652</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v10.i4.pp1944-1950</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 10, No 4: December 2019; 1944-1950</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v10.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/18652/12924</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2019 Mohmmad Ahmad, Sheeraz Kirmani</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>