An efficient grid-connected solar PV system with a fault-tolerant mechanism to mitigate the voltage disturbances
International Journal of Power Electronics and Drive Systems · Vol. 17 No. 1 (2026) · hlm. 282–292
ISSN 2722-256X, 2088-8694
Terbit 2026-03-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
One of the most effective renewable energy solutions for long-term power generation is a solar photovoltaic (PV) system that is connected to the grid. However, power quality and system reliability can be significantly impacted by grid-side voltage disturbances such as sag, swell, and faults. To reduce voltage fluctuations and improve grid stability, this study proposes an effective fault-tolerant (FT) solar PV system coupled with a dynamic voltage restorer (DVR). The adaptive DVR-based control method, which dynamically injects compensatory voltages based on disturbance amplitude to ensure uninterrupted and distortion-free power delivery, is the feature that makes this study unique. MATLAB/Simulink is used to model and simulate the system to assess its dynamic response under fault, sag, and swell situations. IEEE 519 standards are met by the suggested design, which produces average total harmonic distortion (THD) values of 0.59%, 1.16%, and 1.55% for 50%, 100% sag/swell, and three-phase fault circumstances, respectively. This indicates that even in challenging grid situations, the DVR can sustain high-quality voltage profiles. For implementation in renewable-rich or weak grid networks, the suggested FT-DVR configuration provides a workable and affordable solution that guarantees better voltage regulation, less harmonic distortion, and increased operational dependability for upcoming smart-grid integration.
Jaringan kolaborasi para penulis
4 penulis ·
4 tautan kepenulisan bersama
· 2 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Visvesvaraya Technological University B.M.S. College of Engineering Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulis Organisasi Artikel bersama
R. Neela Afiliasi tidak diketahui 2
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">An efficient grid-connected solar PV system with a fault-tolerant mechanism to mitigate the voltage disturbances</dc:title>
<dc:creator>Jayakumar, N.</dc:creator>
<dc:creator>Vighneshwari, B. Devi</dc:creator>
<dc:creator>Prema, V.</dc:creator>
<dc:subject xml:lang="en-US">dynamic voltage restorer; fault-tolerant; grid-connected system; solar PV; voltage disturbances</dc:subject>
<dc:description xml:lang="en-US">One of the most effective renewable energy solutions for long-term power generation is a solar photovoltaic (PV) system that is connected to the grid. However, power quality and system reliability can be significantly impacted by grid-side voltage disturbances such as sag, swell, and faults. To reduce voltage fluctuations and improve grid stability, this study proposes an effective fault-tolerant (FT) solar PV system coupled with a dynamic voltage restorer (DVR). The adaptive DVR-based control method, which dynamically injects compensatory voltages based on disturbance amplitude to ensure uninterrupted and distortion-free power delivery, is the feature that makes this study unique. MATLAB/Simulink is used to model and simulate the system to assess its dynamic response under fault, sag, and swell situations. IEEE 519 standards are met by the suggested design, which produces average total harmonic distortion (THD) values of 0.59%, 1.16%, and 1.55% for 50%, 100% sag/swell, and three-phase fault circumstances, respectively. This indicates that even in challenging grid situations, the DVR can sustain high-quality voltage profiles. For implementation in renewable-rich or weak grid networks, the suggested FT-DVR configuration provides a workable and affordable solution that guarantees better voltage regulation, less harmonic distortion, and increased operational dependability for upcoming smart-grid integration.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2026-03-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24382</dc:identifier>
<dc:identifier>10.11591/ijpeds.v17.i1.pp282-292</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 17, No 1: March 2026; 282-292</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v17.i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24382/15154</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2026 N. Jayakumar, B. Devi Vighneshwari, V. Prema</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Jayakumar, N., Vighneshwari, B. D., & Prema, V. (2026). An efficient grid-connected solar PV system with a fault-tolerant mechanism to mitigate the voltage disturbances. International Journal of Power Electronics and Drive Systems, 17(1), 282–292. https://doi.org/10.11591/ijpeds.v17.i1.pp282-292
Salin
IEEE
N. Jayakumar, B. D. Vighneshwari, and V. Prema, “An efficient grid-connected solar PV system with a fault-tolerant mechanism to mitigate the voltage disturbances,” International Journal of Power Electronics and Drive Systems, vol. 17, no. 1, pp. 282–292, 2026, doi: 10.11591/ijpeds.v17.i1.pp282-292.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.