Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

A simplified model design of MMC-HVDC transmission system for steady state and transient stability analyses

International Journal of Power Electronics and Drive Systems · Vol. 14 No. 2 (2023) · hlm. 934–947

DOI
10.11591/ijpeds.v14.i2.pp934-947
ISSN
2722-256X, 2088-8694
Terbit
2023-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

A simplified model of a modular multilevel converter (MMC) implemented on a high voltage direct current (HVDC) transmission system is presented in this study for the analyses of steady-state and transient stabilities. The simplified model design’s goal is to reduce the complicated modeling of the MMC circuit as well as the simulation time of the analysis. The validity of the model design has been examined using the PSCAD/EMTDC simulation program, where the simulation outcomes of the detailed model and the simplified model are contrasted. It has been established that the simplified model is accurate enough and that simulation time can be substantially decreased. It is concluded that the suggested model design is very significant as a simplified model for analyzing the steady state and transient stabilities of MMC-HVDC transmission system.

Kata kunci

Jaringan kolaborasi para penulis

11 penulis · 31 tautan kepenulisan bersama · 13 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Kitami Institute of Technology
  • Universitas Muhammadiyah Surabaya
  • Diponegoro University
  • Tun Hussein Onn University of Malaysia
  • Universiti Teknologi MARA
  • Universitas Jember
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Widjonarko WidjonarkoDiponegoro University1
Wahyu Mulyo UtomoTun Hussein Onn University of Malaysia1
Saodah OmarUniversiti Teknologi MARA1
Fatah Ridha BaskaraUniversitas Jember1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">A simplified model design of MMC-HVDC transmission system for steady state and transient stability analyses</dc:title>
	<dc:creator>Rosyadi, Marwan</dc:creator>
	<dc:creator>Umemura, Atsushi</dc:creator>
	<dc:creator>Takahashi, Rion</dc:creator>
	<dc:creator>Tamura, Junji</dc:creator>
	<dc:creator>Uchiumi, Takamori</dc:creator>
	<dc:creator>Mori, Masanori</dc:creator>
	<dc:creator>Miyata, Hiroki</dc:creator>
	<dc:subject xml:lang="en-US">HVDC transmission system; modular multi-level converter; simplified modeling; steady state analysis; transient analysis</dc:subject>
	<dc:description xml:lang="en-US">A simplified model of a modular multilevel converter (MMC) implemented on a high voltage direct current (HVDC) transmission system is presented in this study for the analyses of steady-state and transient stabilities. The simplified model design’s goal is to reduce the complicated modeling of the MMC circuit as well as the simulation time of the analysis. The validity of the model design has been examined using the PSCAD/EMTDC simulation program, where the simulation outcomes of the detailed model and the simplified model are contrasted. It has been established that the simplified model is accurate enough and that simulation time can be substantially decreased. It is concluded that the suggested model design is very significant as a simplified model for analyzing the steady state and transient stabilities of MMC-HVDC transmission system.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Ministry of Research, Technology, and Higher Education Republic of Indonesia</dc:contributor>
	<dc:date>2023-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22385</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v14.i2.pp934-947</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 2: June 2023; 934-947</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v14.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22385/14170</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Marwan Rosyadi, Atsushi Umemura, Rion Takahashi, Junji Tamura, Takamori Uchiumi, Masanori Mori, Hiroki Miyata</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>