Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Performance analysis of fifteen level reduced device count asymmetrical multilevel inverter

International Journal of Power Electronics and Drive Systems · Vol. 15 No. 4 (2024) · hlm. 2243–2252

DOI
10.11591/ijpeds.v15.i4.pp2243-2252
ISSN
2722-256X, 2088-8694
Terbit
2024-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In this article, a fifteen-level reduced device count asymmetrical multilevel inverter is introduced for electric vehicle applications. This novel multilevel inverter topology minimizes the power switches required. Control of the proposed inverter is accomplished via the nearest-level control method. In a typical multilevel inverter, ten to twelve switches are used to create the fifteen levels. A high number of switches are used in traditional multilevel inverters, which increases the distortion from all harmonics, switching losses, cost, and cost per switch. Only nine switches are needed for the suggested architecture. It significantly minimizes the total harmonic distortion by 5% and lowers the switching losses, low-order harmonics, and complexity. The efficiency of the suggested multilevel inverter (MLI) is 98.35%.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 21 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Karpagam Academy of Higher Education
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 29 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Performance analysis of fifteen level reduced device count asymmetrical multilevel inverter</dc:title>
	<dc:creator>Manivel, Murugesan</dc:creator>
	<dc:creator>Palani, Lakshmanan</dc:creator>
	<dc:creator>Subramani, Sivaranjani</dc:creator>
	<dc:creator>Thiagarajan, Bharani Prakash</dc:creator>
	<dc:creator>Kannusamy, Divya</dc:creator>
	<dc:creator>Devasahayam, Jebakumar Immanuel</dc:creator>
	<dc:creator>Vijayalakshmi, V. J.</dc:creator>
	<dc:subject xml:lang="en-US">Alternating current; direct current; multilevel inverter; nearest level control; total harmonic distortion</dc:subject>
	<dc:description xml:lang="en-US">In this article, a fifteen-level reduced device count asymmetrical multilevel inverter is introduced for electric vehicle applications. This novel multilevel inverter topology minimizes the power switches required. Control of the proposed inverter is accomplished via the nearest-level control method. In a typical multilevel inverter, ten to twelve switches are used to create the fifteen levels. A high number of switches are used in traditional multilevel inverters, which increases the distortion from all harmonics, switching losses, cost, and cost per switch. Only nine switches are needed for the suggested architecture. It significantly minimizes the total harmonic distortion by 5% and lowers the switching losses, low-order harmonics, and complexity. The efficiency of the suggested multilevel inverter (MLI) is 98.35%.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23254</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v15.i4.pp2243-2252</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 15, No 4: December 2024; 2243-2252</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v15.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23254/14793</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Murugesan Manivel, Lakshmanan Palani, Sivaranjani Subramaniam, Bharani Prakash Thiagarajan, Divya Kannusamy, Jebakumar Immanuel D, Anandhkumar Varathan</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>