Implementation of the conventional seven-level single-phase symmetrical cascaded h-bridge MLI based on PSIM

International Journal of Power Electronics and Drive Systems · Vol. 11 No. 1 (2020) · hlm. 169–177

DOI
10.11591/ijpeds.v11.i1.pp169-177
ISSN
2722-256X, 2088-8694
Terbit
2020-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Researchers have found interest in the multilevel inverters (MLI) owing to the low total harmonic distortion (THD) associated with their output voltage, as well as their low electromagnetic interference (EMI). The MLI represents an effective and feasible solution for enhancing power demand and minimizing AC waveforms’ harmonics as they generate a preferred level of output voltage as inputs from varying levels of DC voltages. In this paper, the performance of a seven-level cascaded H-bridge MLI with an asymmetrical number of power switches was evaluated. The simulation performance is shown to validate the operating principle of the single-phase cascaded H-bridge inverter. To control the MLI, a pulse width modulation approach was utilized. The operating principle of the MLI was verified via simulation using PSIM software.

Jaringan kolaborasi para penulis

8 penulis · 21 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Middle Technical University
  • Al-Farahidi University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Adnan Hussein AliMiddle Technical University2
Ali Abdulwahhab AbdulrazzaqMiddle Technical University2
Waleed Khalid Al‐AzzawiAl-Farahidi University1
Asaad A. AlZubaidiAfiliasi tidak diketahui1
Laith Abdul KhaliqAfiliasi tidak diketahui1
Mohanad Sameer JabbarAfiliasi tidak diketahui1
Thaer Abdulwahhab ShihabAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Implementation of the conventional seven-level single-phase symmetrical cascaded h-bridge MLI based on PSIM</dc:title>
	<dc:creator>Hamad, Hassan Salman</dc:creator>
	<dc:description xml:lang="en-US">Researchers have found interest in the multilevel inverters (MLI) owing to the low total harmonic distortion (THD) associated with their output voltage, as well as their low electromagnetic interference (EMI). The MLI represents an effective and feasible solution for enhancing power demand and minimizing AC waveforms’ harmonics as they generate a preferred level of output voltage as inputs from varying levels of DC voltages. In this paper, the performance of a seven-level cascaded H-bridge MLI with an asymmetrical number of power switches was evaluated. The simulation performance is shown to validate the operating principle of the single-phase cascaded H-bridge inverter. To control the MLI, a pulse width modulation approach was utilized. The operating principle of the MLI was verified via simulation using PSIM software.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20277</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i1.pp169-177</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 1: March 2020; 169-177</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20277/12986</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Hassan Salman Hamad</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>