Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Stator interturn short circuit fault identification in DFIG and its analysis using an artificial neural network

International Journal of Power Electronics and Drive Systems · Vol. 17 No. 3 (2026) · hlm. 1643–1658

DOI
10.11591/ijpeds.v17.i3.pp1643-1658
ISSN
2722-256X, 2088-8694
Terbit
2026-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Inter-turn short circuit (ITSC) issues are a common electrical failure mainly caused by the deterioration of winding insulation in the machine over time. Failing to detect such issues early can lead to catastrophic consequences. This article investigates the interturn fault in the stator winding of a doubly-fed induction generator (DFIG) used in wind turbines. A flux linkage difference vector (FLDV) model is introduced in this study for fault detection. Additionally, an artificial neural network (ANN) model is proposed to classify these faults. Specifically, a short-circuit fault is induced in each phase of the stator winding, and the faults are classified by assigning different magnitudes to the respective phases. The ANN is trained to identify which phase contains an interturn fault, with output waveform amplitudes of 1, 2, or 3 corresponding to faults in phases "a," "b," and "c." If no fault is present, the waveform magnitude is designated as "0." This approach enables early fault diagnosis by analyzing waveform patterns, thereby preventing overheating caused by short circuits and avoiding severe, irreversible damage to the windings.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • GLA University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Indresh YadavGLA University1
Gaurav Kumar GuptaGLA University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Stator interturn short circuit fault identification in DFIG and its analysis using an artificial neural network</dc:title>
	<dc:creator>Kushwaha, Vivek</dc:creator>
	<dc:creator>Maurya, Sanjay Kumar</dc:creator>
	<dc:creator>Yadav, Arvind Kumar</dc:creator>
	<dc:subject xml:lang="en-US">artificial neural network; doubly-fed induction generator; inter-turn short circuit fault; simulation; stator current</dc:subject>
	<dc:description xml:lang="en-US">Inter-turn short circuit (ITSC) issues are a common electrical failure mainly caused by the deterioration of winding insulation in the machine over time. Failing to detect such issues early can lead to catastrophic consequences. This article investigates the interturn fault in the stator winding of a doubly-fed induction generator (DFIG) used in wind turbines. A flux linkage difference vector (FLDV) model is introduced in this study for fault detection. Additionally, an artificial neural network (ANN) model is proposed to classify these faults. Specifically, a short-circuit fault is induced in each phase of the stator winding, and the faults are classified by assigning different magnitudes to the respective phases. The ANN is trained to identify which phase contains an interturn fault, with output waveform amplitudes of 1, 2, or 3 corresponding to faults in phases "a," "b," and "c." If no fault is present, the waveform magnitude is designated as "0." This approach enables early fault diagnosis by analyzing waveform patterns, thereby preventing overheating caused by short circuits and avoiding severe, irreversible damage to the windings.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/25070</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v17.i3.pp1643-1658</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 17, No 3: September 2026; 1643-1658</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v17.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/25070/15299</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Vivek Kushwaha, Sanjay Kumar Maurya, Arvind Kumar Yadav</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>