Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Adaptive control strategies for enhancing the performance and stability of renewable energy systems

International Journal of Power Electronics and Drive Systems · Vol. 16 No. 4 (2025) · hlm. 2411–2418

DOI
10.11591/ijpeds.v16.i4.pp2411-2418
ISSN
2722-256X, 2088-8694
Terbit
2025-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The comparison done in this paper uses two control strategies for a solar-fed three-phase inverter, one with standard sinusoidal pulse width modulation (SPWM) and the other with unified space vector PWM (USPWM), equipped with adaptive voltage control (AVC) and a load current observer (LCO). A photovoltaic (PV) source feeds into a controlled DC link, which in turn supplies a DC voltage to the inverter powering an RL load. From the simulation, it is clear that although SPWM meets the output standards, it has increased total harmonic distortion (THD) and slower transient response. Alternatively, using USPWM control decreased THD to 3.01% and made the system respond in 11 ms, compared to 22 ms before. The new method provides better efficiency and better power quality when used with dynamic loads.

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 16 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • SR University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tharinaematam BhavaniSR University1
Md Mujahid IrfanSR University1
Shaik RafikiranAfiliasi tidak diketahui1
Gaddala AnushaSR University1
Ram Ragotham DeshmukhSR University1
CH Hussaian BashaSR University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Adaptive control strategies for enhancing the performance and stability of renewable energy systems</dc:title>
	<dc:creator>Kunumalla, Sreedevi</dc:creator>
	<dc:creator>Rajababu, Durgam</dc:creator>
	<dc:creator>Sudhakar, A. V. V.</dc:creator>
	<dc:subject xml:lang="en-US">adaptive voltage control; load current observer; SPWM; solar photovoltaic; total harmonic distortion; USPWM</dc:subject>
	<dc:description xml:lang="en-US">The comparison done in this paper uses two control strategies for a solar-fed three-phase inverter, one with standard sinusoidal pulse width modulation (SPWM) and the other with unified space vector PWM (USPWM), equipped with adaptive voltage control (AVC) and a load current observer (LCO). A photovoltaic (PV) source feeds into a controlled DC link, which in turn supplies a DC voltage to the inverter powering an RL load. From the simulation, it is clear that although SPWM meets the output standards, it has increased total harmonic distortion (THD) and slower transient response. Alternatively, using USPWM control decreased THD to 3.01% and made the system respond in 11 ms, compared to 22 ms before. The new method provides better efficiency and better power quality when used with dynamic loads.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23838</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v16.i4.pp2411-2418</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 16, No 4: December 2025; 2411-2418</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v16.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23838/15084</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Sreedevi Kunumalla, Durgam Rajababu, A. V. V. Sudhakar</dc:rights>