Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Line and Grid Impedance Impact on the Performances of a Parallel Connected Modular Inverter System

International Journal of Power Electronics and Drive Systems · Vol. 6 No. 1 (2015) · hlm. 100–108

DOI
10.11591/ijpeds.v6.i1.pp100-108
ISSN
2722-256X, 2088-8694
Terbit
2015-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

With the rising fuel cost, increasing demand of power and the concerns for global climate change, the use of clean energy make the connection of power electronics building bloc in the heart of the current research. The high output current applications make the parallel connection of modular inverters to be a solution for the use of low power building block inverters where the output power cannot be handled by a single inverter configuration. In this context, average-modeling using average phase–leg technique allows the n-parallel connected inverters to be analyzed accurately and rapidly without requiring the complexity of the full switched inverter topology. The obtained analytical solution along with the equivalent circuit model makes easier the design of the control loop. The analytical solution of the n-parallel connected inverters shows the impact of the line and grid impedance on the performance of the overall system. The impact of this coupling has to be investigated such that the main feature of paralleling inverters is guaranteed and that the inverter mode of operation will not be compromised. The main advantage of paralleling inverters can be lost for a certain coupling impedance considerations.

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Polytechnic School of Algiers
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Line and Grid Impedance Impact on the Performances of a Parallel Connected Modular Inverter System</dc:title>
	<dc:creator>Zebbadji, Tahar</dc:creator>
	<dc:creator>Hadji, Seddik</dc:creator>
	<dc:creator>Ibtiouen, Rachid</dc:creator>
	<dc:description xml:lang="en-US">With the rising fuel cost, increasing demand of power and the concerns for global climate change, the use of clean energy make the connection of power electronics building bloc in the heart of the current research. The high output current applications make the parallel connection of modular inverters to be a solution for the use of low power building block inverters where the output power cannot be handled by a single inverter configuration. In this context, average-modeling using average phase–leg technique allows the n-parallel connected inverters to be analyzed accurately and rapidly without requiring the complexity of the full switched inverter topology. The obtained analytical solution along with the equivalent circuit model makes easier the design of the control loop. The analytical solution of the n-parallel connected inverters shows the impact of the line and grid impedance on the performance of the overall system. The impact of this coupling has to be investigated such that the main feature of paralleling inverters is guaranteed and that the inverter mode of operation will not be compromised. The main advantage of paralleling inverters can be lost for a certain coupling impedance considerations.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:date>2015-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5106</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v6.i1.pp100-108</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 6, No 1: March 2015; 100-108</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v6.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5106/4550</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2015 Tahar Zebbadji, Seddik Hadji, Rachid Ibtiouen</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>