Abstrak
This study introduces a refined current feedback instrumentation amplifier (CFIA) specifically designed for amplifying biopotential signals that originate from resistive-bridge sensors. The proposed architecture uniquely incorporates a multipath chopper-stabilized CFIA which has been developed to minimize the effects of bridge offsets, while maintaining low power usage, high input impedance, and reduced noise characteristics. The engineering blueprint employs a ripple reduction loop (RRL) to mitigate output ripple caused by chopper up-modulation. To speed up offset cancellation and to limit the offset caused by bridge mismatch, an automatic offset cancellation loop (AOCL) circuit is integrated within the analog front end (AFE). Crafted using a conventional 0.18 µm CMOS process, the CFIA in this design provides adjustable gain between 20.35 dB to 55.14 dB, with a power supply rejection ratio (PSRR) and a common mode rejection ratio (CMRR) of 103 dB and 114 dB, respectively. The system demonstrates an input-referred noise (IRN) value of 16 ηV/√Hz at 200 Hz frequency, equivalent to a noise efficiency factor (NEF) of 5.18. Operating from a supply voltage of 1.8V, the AFE shows a power consumption of 291 μW.
Jaringan kolaborasi para penulis
20 penulis ·
73 tautan kepenulisan bersama
· 14 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Sidi Mohamed Ben Abdellah University Université Privée de Fès Université du Québec
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Biopotential multi-path current feedback instrumentation amplifier with automatic offset cancellation loop for resistive bridge microsensors</dc:title>
<dc:creator>Laababid, Younes</dc:creator>
<dc:creator>El Khadiri, Karim</dc:creator>
<dc:creator>Tahiri, Ahmed</dc:creator>
<dc:subject xml:lang="en-US">AOCL; CMRR; multi-path CFIA; NEF; RRL</dc:subject>
<dc:description xml:lang="en-US">This study introduces a refined current feedback instrumentation amplifier (CFIA) specifically designed for amplifying biopotential signals that originate from resistive-bridge sensors. The proposed architecture uniquely incorporates a multipath chopper-stabilized CFIA which has been developed to minimize the effects of bridge offsets, while maintaining low power usage, high input impedance, and reduced noise characteristics. The engineering blueprint employs a ripple reduction loop (RRL) to mitigate output ripple caused by chopper up-modulation. To speed up offset cancellation and to limit the offset caused by bridge mismatch, an automatic offset cancellation loop (AOCL) circuit is integrated within the analog front end (AFE). Crafted using a conventional 0.18 µm CMOS process, the CFIA in this design provides adjustable gain between 20.35 dB to 55.14 dB, with a power supply rejection ratio (PSRR) and a common mode rejection ratio (CMRR) of 103 dB and 114 dB, respectively. The system demonstrates an input-referred noise (IRN) value of 16 ηV/√Hz at 200 Hz frequency, equivalent to a noise efficiency factor (NEF) of 5.18. Operating from a supply voltage of 1.8V, the AFE shows a power consumption of 291 μW.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2023-12-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22755</dc:identifier>
<dc:identifier>10.11591/ijpeds.v14.i4.pp2107-2118</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 4: December 2023; 2107-2118</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v14.i4</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22755/14337</dc:relation>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/downloadSuppFile/22755/3224</dc:relation>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/downloadSuppFile/22755/3225</dc:relation>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/downloadSuppFile/22755/3226</dc:relation>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/downloadSuppFile/22755/3227</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2023 YOUNES LAABABID, KARIM EL KHADIRI, AHMED TAHIRI</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Laababid, Y., El Khadiri, K., & Tahiri, A. (2023). Biopotential multi-path current feedback instrumentation amplifier with automatic offset cancellation loop for resistive bridge microsensors. International Journal of Power Electronics and Drive Systems, 14(4), 2107–2118. https://doi.org/10.11591/ijpeds.v14.i4.pp2107-2118
Salin
IEEE
Y. Laababid, K. El Khadiri, and A. Tahiri, “Biopotential multi-path current feedback instrumentation amplifier with automatic offset cancellation loop for resistive bridge microsensors,” International Journal of Power Electronics and Drive Systems, vol. 14, no. 4, pp. 2107–2118, 2023, doi: 10.11591/ijpeds.v14.i4.pp2107-2118.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.