Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Appropriate Switching State Selection to Avoid Capacitor Imbalance in Five-Level NPC

International Journal of Power Electronics and Drive Systems · Vol. 9 No. 1 (2018) · hlm. 276–285

DOI
10.11591/ijpeds.v9.i1.pp276-285
ISSN
2722-256X, 2088-8694
Terbit
2018-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

An intrinsic problem with neutral point clamped (NPC) multilevel inverters (MLI) is unbalance of capacitor voltage. There are many mitigation techniques well established in the literature to balance the neutral point voltage for 3-level inverter. These techniques employ either Carrier based pulse width modulation (CBPWM), Space vector pulse width modulation (SVPWM) or hybrid of both the PWM techniques. Balancing becomes complicated as the level of the inverter increases due to addition of capacitor junctions. The imbalance in capacitor voltages may cause uneven voltage distribution among switching devices and sometimes may cause failure. It also increases harmonic content in its output waveform. This paper develops new modulation scheme for balancing capacitor voltages for Five-level inverter.The scheme is a hybrid PWM which is a combination of both CBPWM and SVPWM techniques. As per this scheme CBPWM is applied to meet the load demand and at the zero crossings of the reference signal, CBPWM is blocked and for one carrier cycle. During this SVPWM is applied with appropriate switching state selection to neutralize the imbalance in capacitor voltage.

Jaringan kolaborasi para penulis

6 penulis · 7 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Koneru Lakshmaiah Education Foundation
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Gaddipati Geetha RavaliKoneru Lakshmaiah Education Foundation1
Sudha Rani DonepudiAfiliasi tidak diketahui1
Swathi KarikeKoneru Lakshmaiah Education Foundation1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Appropriate Switching State Selection to Avoid Capacitor Imbalance in Five-Level NPC</dc:title>
	<dc:creator>Narasimha Raju, Kuthuri</dc:creator>
	<dc:creator>Obbu, Chandra Sekhar</dc:creator>
	<dc:creator>M, Ramamoorthy</dc:creator>
	<dc:subject xml:lang="en-US"></dc:subject>
	<dc:description xml:lang="en-US">An intrinsic problem with neutral point clamped (NPC) multilevel inverters (MLI) is unbalance of capacitor voltage. There are many mitigation techniques well established in the literature to balance the neutral point voltage for 3-level inverter. These techniques employ either Carrier based pulse width modulation (CBPWM), Space vector pulse width modulation (SVPWM) or hybrid of both the PWM techniques. Balancing becomes complicated as the level of the inverter increases due to addition of capacitor junctions. The imbalance in capacitor voltages may cause uneven voltage distribution among switching devices and sometimes may cause failure. It also increases harmonic content in its output waveform. This paper develops new modulation scheme for balancing capacitor voltages for Five-level inverter .The scheme is a hybrid PWM which is a combination of both CBPWM and SVPWM techniques. As per this scheme CBPWM is applied to meet the load demand and at the zero crossings of the reference signal, CBPWM is blocked and for one carrier cycle. During this SVPWM is applied with   appropriate switching state selection to neutralize the imbalance in capacitor voltage.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/9925</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v9.i1.pp276-285</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 9, No 1: March 2018; 276-285</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v9.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/9925/9630</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 Kuthuri Narasimha Raju, Chandra Sekhar Obbu, Ramamoorthy M</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>