Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Time-domain performance of QBC with self-lift circuit

International Journal of Power Electronics and Drive Systems · Vol. 16 No. 4 (2025) · hlm. 2491–2499

DOI
10.11591/ijpeds.v16.i4.pp2491-2499
ISSN
2722-256X, 2088-8694
Terbit
2025-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This study examines the performance of a high-gain quadratic boost converter (QBC) coupled with a self-lift circuit under two control methodologies: sliding mode control (SMC) and fractional-order proportional integral derivative (FOPID) control. The QBC topology is used because it can boost voltage significantly, which is especially useful for renewable energy applications. Simulation studies show that both controllers can control the output voltage of the converter, but the FOPID controller works better in dynamic situations. In particular, it makes settling happen faster, cuts down on overshoot, and lowers steady-state error compared to the SMC method. The overall results show that the FOPID controller is a good choice for improving stability and transient response. This makes it a good choice for advanced high-performance power electronic systems.

Kata kunci

Jaringan kolaborasi para penulis

16 penulis · 41 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • SRM Institute of Science and Technology
  • Sathyabama Institute of Science and Technology
  • St. Joseph’s College of Engineering
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
R. Samuel Rajesh BabuSathyabama Institute of Science and Technology3
R. PalanisamySRM Institute of Science and Technology2
D ShobanaAfiliasi tidak diketahui2
Dhandapani MeenaSRM Institute of Science and Technology2
S. Ganesh KumaranAfiliasi tidak diketahui2
K. SelvakumarSRM Institute of Science and Technology1
Thamizh ThentralAfiliasi tidak diketahui1
Usha SengamalaiSRM Institute of Science and Technology1
Kalyanasundaram VakesanSRM Institute of Science and Technology1
Vidyasagar SugavanamSRM Institute of Science and Technology1
Somasundaram DeepaAfiliasi tidak diketahui1
N. AnipriyaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Time-domain performance of QBC with self-lift circuit</dc:title>
	<dc:creator>Ramamurthi, Subbulakshmy</dc:creator>
	<dc:creator>Velmurugan, Palani</dc:creator>
	<dc:creator>Devendiren, Shobana</dc:creator>
	<dc:creator>Manivannan, Soundarapandiyan</dc:creator>
	<dc:subject xml:lang="en-US">dynamic performance; FOPID; quadratic boost converter; self-lift circuit; sliding mode controller</dc:subject>
	<dc:description xml:lang="en-US">This study examines the performance of a high-gain quadratic boost converter (QBC) coupled with a self-lift circuit under two control methodologies: sliding mode control (SMC) and fractional-order proportional integral derivative (FOPID) control. The QBC topology is used because it can boost voltage significantly, which is especially useful for renewable energy applications. Simulation studies show that both controllers can control the output voltage of the converter, but the FOPID controller works better in dynamic situations. In particular, it makes settling happen faster, cuts down on overshoot, and lowers steady-state error compared to the SMC method. The overall results show that the FOPID controller is a good choice for improving stability and transient response. This makes it a good choice for advanced high-performance power electronic systems.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24033</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v16.i4.pp2491-2499</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 16, No 4: December 2025; 2491-2499</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v16.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24033/15091</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Subbulakshmy Ramamurthi, Palani Velmurugan, Shobana Devendiren, Soundarapandiyan Manivannan</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>