Abstrak

In This paper we present experimental comparative study of feedBack Linearized and Proportional Integral (PI) Controller of the DC bus voltage of three phase shunt Active Power Filter (APF). The FeedBack Linearized and PI controllers are introduced to improve tracking performance characteristics, power quality and minimized consumption of the reactive power. The algorithm used to identify the reference currents is based on the Self Tuning Filter (STF). The firing pulses of the IGBTs inverter are generated using a hysteresis current controller; which is implemented on an analogue card. Finally, the above study, under steady state and transient conditions, is illustrated with signal-flow graphs and corresponding analysis. This study was verified by experimental tests on hardware prototype based on dSPACE-1104. The experimental results show the feasibility and the effectiveness of the designed active filter, associated with Feedback Linearized and PI controllers and are capability in meeting the IEEE 519-1992 recommended harmonic standard limits.

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University Mohamed Boudiaf of M'sila
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Experimental Comparative Study of Feedback Linearized Controller and Proportional Integral Controller of the DC Bus Voltage of Three-phase Shunt Active Power Filter</dc:title>
	<dc:creator>Ghadbane, Ismail</dc:creator>
	<dc:creator>Benchouia, Mohamed Toufik</dc:creator>
	<dc:description xml:lang="en-US">In This paper we present experimental comparative study of feedBack Linearized and Proportional Integral (PI) Controller of the DC bus voltage of three phase shunt Active Power Filter (APF). The FeedBack Linearized and PI controllers are introduced to improve tracking performance characteristics, power quality and minimized consumption of the reactive power. The algorithm used to identify the reference currents is based on the Self Tuning Filter (STF). The firing pulses of the IGBTs inverter are generated using a hysteresis current controller; which is implemented on an analogue card. Finally, the above study, under steady state and transient conditions, is illustrated with signal-flow graphs and corresponding analysis. This study was verified by experimental tests on hardware prototype based on dSPACE-1104. The experimental results show the feasibility and the effectiveness of the designed active filter, associated with Feedback Linearized and PI controllers and are capability in meeting the IEEE 519-1992 recommended harmonic standard limits.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2017-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/9250</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i4.pp1481-1493</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 4: December 2017; 1481-1493</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/9250/7738</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Ismail Ghadbane, Mohamed Toufik Benchouia</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>