Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Impact of static synchronous compensator STATCOM installation in power quality improvement

International Journal of Power Electronics and Drive Systems · Vol. 13 No. 4 (2022) · hlm. 2296–2304

DOI
10.11591/ijpeds.v13.i4.pp2296-2304
ISSN
2722-256X, 2088-8694
Terbit
2022-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The present work investigates the flexible AC transmission system (FACTS) device's role to improve the voltage stability for a distribution network of various types of loads. Our analysis was based on using a static synchronous compensator (STATCOM) device over a test distribution system. Firstly, a detailed description of the mathematical model used in our system is presented. Then we studied the effect of inductive and capacitive loads with and without STATCOM. To investigate the efficacy and robustness of using STATCOM in a distribution network, a test system is developed using MATLAB/Simulink, where we analyzed the voltage profile in different cases. The results of the simulation demonstrate that the STATCOM plays a critical role in optimizing the voltage profiles of distribution systems, either capacitive or inductive.

Kata kunci

Jaringan kolaborasi para penulis

23 penulis · 80 tautan kepenulisan bersama · 33 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sidi Mohamed Ben Abdellah University
  • Université Ibn-Tofail
  • Université Moulay Ismail de Meknes
  • University of Hassan II Casablanca
  • Majmaah University
  • University of Central Asia
  • Siberian Federal University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Aboubakr El MakriniSidi Mohamed Ben Abdellah University5
Hassan El MoussaouiSidi Mohamed Ben Abdellah University4
Younes BoujoudarSidi Mohamed Ben Abdellah University3
Mohamed AzeroualUniversité Moulay Ismail de Meknes3
Hassan ElmoussaouiAfiliasi tidak diketahui2
Mohamed Amine BenissSidi Mohamed Ben Abdellah University2
Mustapha ZahriUniversité Ibn-Tofail1
Youssef MenchafouSidi Mohamed Ben Abdellah University1
Mohamed HabibiUniversité Ibn-Tofail1
Ayman AljarbouhUniversity of Central Asia1
Lahcen EliysaouyAfiliasi tidak diketahui1
Fatima Zahra BassineUniversity of Hassan II Casablanca1
Aiman J.AlbarakatiMajmaah University1
Alexey KnyazkovSiberian Federal University1
Alhussein BagayogoSidi Mohamed Ben Abdellah University1
Omar KabouriSidi Mohamed Ben Abdellah University1
Youness BoukhrisSidi Mohamed Ben Abdellah University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Impact of static synchronous compensator STATCOM installation in power quality improvement</dc:title>
	<dc:creator>Moufid, Ismail</dc:creator>
	<dc:creator>En-nay, Zineb</dc:creator>
	<dc:creator>Naciri, Soukaina</dc:creator>
	<dc:creator>Moussaoui, Hassan El</dc:creator>
	<dc:creator>Lamhamdi, Tijani</dc:creator>
	<dc:creator>Markhi, Hassane El</dc:creator>
	<dc:subject xml:lang="en-US">FACT device; MATLAB/Simulink; Point of common coupling; STATCOM; Voltage profile</dc:subject>
	<dc:description xml:lang="en-US">The present work investigates the flexible AC transmission system (FACTS) device's role to improve the voltage stability for a distribution network of various types of loads. Our analysis was based on using a static synchronous compensator (STATCOM) device over a test distribution system. Firstly, a detailed description of the mathematical model used in our system is presented. Then we studied the effect of inductive and capacitive loads with and without STATCOM. To investigate the efficacy and robustness of using STATCOM in a distribution network, a test system is developed using MATLAB/Simulink, where we analyzed the voltage profile in different cases. The results of the simulation demonstrate that the STATCOM plays a critical role in optimizing the voltage profiles of distribution systems, either capacitive or inductive.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2022-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22001</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v13.i4.pp2296-2304</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 4: December 2022; 2296-2304</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v13.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22001/14022</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Ismail Moufid, Zineb En-nay, Soukaina Naciri, Hassan El Moussaoui, Tijani Lamhamdi, Hassane El Markhi</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>