Abstrak

In this paper, the voltage stability of the power system is studied during fault conditions. Enhancement of the system’s stability will be achieved by utilizing Flexible AC transmission systems (FACTS) controllers at the best place in the system. The optimum placement of (FACTS) controllers occurred on the most affected bus by the fault in the system (weakest bus). Two approaches have been used in this study to effectively obtain the best location of the (FACTS) controllers in the system. The first method is based on computing the deviation which occurs in the active power and reactive power due to the fault at each load bus at a time. Whereas the second method is performed through exploiting a MATLAB fuzzy set technique utilizing two indices: Line Flow Index (LFI) and Voltage Profile Index (VPI) during fault and steady-state conditions. The results show that both of these indices resulted in the same bus as the best location. Remedial actions in the attempt at improving in the stability of the power system are discussed taking the advantage of using (FACTS) compensation (SVC) and (STATCOM) at the most vulnerable system buses. In this work, MATLAB program with an IEEE 24 bus system is examined.

Jaringan kolaborasi para penulis

8 penulis · 12 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Tikrit
  • University of Gabès
  • Al-Qalam University
  • University of Sfax
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Jamal A. HameedUniversity of Tikrit1
Mohammed M. SultanUniversity of Tikrit1
Musa A. HameedUniversity of Tikrit1
Nabil DerbelUniversity of Sfax1
Wassan Adnan HashimAl-Qalam University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Selection the optimum place of FACTS devices using fuzzy control system</dc:title>
	<dc:creator>Hameed, Jawad</dc:creator>
	<dc:creator>Mohammed, Hameed Ali</dc:creator>
	<dc:creator>Saeed, Amer T.</dc:creator>
	<dc:description xml:lang="en-US">In this paper, the voltage stability of the power system is studied during fault conditions. Enhancement of the system’s stability will be achieved by utilizing Flexible AC transmission systems (FACTS) controllers at the best place in the system. The optimum placement of (FACTS) controllers occurred on the most affected bus by the fault in the system (weakest bus). Two approaches have been used in this study to effectively obtain the best location of the (FACTS) controllers in the system. The first method is based on computing the deviation which occurs in the active power and reactive power due to the fault at each load bus at a time. Whereas the second method is performed through exploiting a MATLAB fuzzy set technique utilizing two indices: Line Flow Index (LFI) and Voltage Profile Index (VPI) during fault and steady-state conditions. The results show that both of these indices resulted in the same bus as the best location. Remedial actions in the attempt at improving in the stability of the power system are discussed taking the advantage of using (FACTS) compensation (SVC) and (STATCOM) at the most vulnerable system buses. In this work, MATLAB program with an IEEE 24 bus system is examined.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20644</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i4.pp1805-1815</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 4: December 2020; 1805-1815</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20644/13259</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Jawad Hameed, Hameed Ali Mohammed, Amer T. Saeed</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>