Akses terbuka
Jurnal
SINTA 1
Controlling the significance of BLDC motor internal faults using dual examine algorithm in electric vehicle applications
International Journal of Power Electronics and Drive Systems · Vol. 14 No. 4 (2023) · hlm. 1946–1954
ISSN 2722-256X, 2088-8694
Terbit 2023-12-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
This paper presents dual examine algorithm (DEA) to reduce residual error as well as to provide accurate phase currents without any distortion for a closed loop brushless direct current (BLDC) motor of an electric vehicle (EV). The underlying technology of DEA is a hybrid of the tabu search optimization (TSO) method and the genetic algorithm (GA). During closed loop operation of BLDC motor residual error is introduced by the discrepancy between the actual and reference speed, and the phase current distortion lowers the efficiency of the machine as a result machine performance is degraded. To address these issues, GA algorithm calculates the necessary parameters for the controller to produce precise current without distortion based on stator phase currents, and the suggested TSO algorithm limits the repeated operations in the PID controller to reduce the residual error to the greatest degree feasible. After primary examining, dual examine process initiate the transposing operation such as TSO is used to prove and calculate the phase current controller parameters, and GA is used to correct for remaining inaccuracy. To validate the proposed DEA algorithm is compared with advanced particle swarm optimization (APSO). The results verified the superiority of proposed DEA algorithm using MATLAB/Simulink platform.
Jaringan kolaborasi para penulis
6 penulis ·
9 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
National Institute of Technology Andhra Pradesh Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Controlling the significance of BLDC motor internal faults using dual examine algorithm in electric vehicle applications</dc:title>
<dc:creator>Gaurav, Gaurav</dc:creator>
<dc:creator>Nakka, Jayaram</dc:creator>
<dc:creator>Obulesu, Dakka</dc:creator>
<dc:creator>Arandhakar, Sairaj</dc:creator>
<dc:subject xml:lang="en-US">aspiration criteria; dual examine algorithm; electric vehicle; genetic algorithm; phase current distortion; residual error</dc:subject>
<dc:description xml:lang="en-US">This paper presents dual examine algorithm (DEA) to reduce residual error as well as to provide accurate phase currents without any distortion for a closed loop brushless direct current (BLDC) motor of an electric vehicle (EV). The underlying technology of DEA is a hybrid of the tabu search optimization (TSO) method and the genetic algorithm (GA). During closed loop operation of BLDC motor residual error is introduced by the discrepancy between the actual and reference speed, and the phase current distortion lowers the efficiency of the machine as a result machine performance is degraded. To address these issues, GA algorithm calculates the necessary parameters for the controller to produce precise current without distortion based on stator phase currents, and the suggested TSO algorithm limits the repeated operations in the PID controller to reduce the residual error to the greatest degree feasible. After primary examining, dual examine process initiate the transposing operation such as TSO is used to prove and calculate the phase current controller parameters, and GA is used to correct for remaining inaccuracy. To validate the proposed DEA algorithm is compared with advanced particle swarm optimization (APSO). The results verified the superiority of proposed DEA algorithm using MATLAB/Simulink platform.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US">NA</dc:contributor>
<dc:date>2023-12-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22707</dc:identifier>
<dc:identifier>10.11591/ijpeds.v14.i4.pp1946-1954</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 4: December 2023; 1946-1954</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v14.i4</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22707/14319</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2023 Sairaj Arandhakar, Gaurav ., Jayaram Nakka, Obulesu Dakka</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Gaurav, G., Nakka, J., Obulesu, D., & Arandhakar, S. (2023). Controlling the significance of BLDC motor internal faults using dual examine algorithm in electric vehicle applications. International Journal of Power Electronics and Drive Systems, 14(4), 1946–1954. https://doi.org/10.11591/ijpeds.v14.i4.pp1946-1954
Salin
IEEE
G. Gaurav, J. Nakka, D. Obulesu, and S. Arandhakar, “Controlling the significance of BLDC motor internal faults using dual examine algorithm in electric vehicle applications,” International Journal of Power Electronics and Drive Systems, vol. 14, no. 4, pp. 1946–1954, 2023, doi: 10.11591/ijpeds.v14.i4.pp1946-1954.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.