Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Performance enhancement of distance relay in presence of unified power flow controller

International Journal of Power Electronics and Drive Systems · Vol. 14 No. 3 (2023) · hlm. 1577–1588

DOI
10.11591/ijpeds.v14.i3.pp1577-1588
ISSN
2722-256X, 2088-8694
Terbit
2023-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The characteristics of the distance relay are devised based on online and fault impedance. The relay uses fault information to react to the expected state; however, integrating the grid with a unified power flow controller (UPFC) might stop the relay from fault-triggered operations, requiring altered relay characteristics. Building relay tripping parameters are among the critical challenges that must be addressed for transmission line distance relays because current transmission networks face higher stress regarding power system operation. Furthermore, the use of flexible AC transmission systems (FACTS) instruments at the transmission level adversely affects distance relay performance due to impedance differences. The UPFC is among the essential FACTS instruments; it comprises shunt and series converters to alter the apparent relay impedance; hence, it was considered for this study, where a test system during fault was assessed to demonstrate the output of the distance relay before and after using the UPFC. MATLAB was used to build scenarios demonstrating the effect of a UPFC located in the transmission line's midsection or end or not using the UPFC. This research offers an analytical technique to determine the probable effects of UPFC on distance relay characteristics. The outcomes provide new relay characteristics for several fault resistances and locations for fault-specific impedance trajectory reactions.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Mosul
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ziyad M. T. SallehUniversity of Mosul1
Hasan Adnan MohammedUniversity of Mosul1
Sinan AlkahdelyUniversity of Mosul1
Omar Sh. AlyozbakyUniversity of Mosul1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Performance enhancement of distance relay in presence of unified power flow controller</dc:title>
	<dc:creator>Al-Kaoaz, Hiba Nadhim A.</dc:creator>
	<dc:creator>Alsammak, Ahmed Nasser B.</dc:creator>
	<dc:subject xml:lang="en-US">Distance relay; FACTS devices; Fault resistance; Measured impedance;  UPFC</dc:subject>
	<dc:description xml:lang="en-US">The characteristics of the distance relay are devised based on online and fault impedance. The relay uses fault information to react to the expected state; however, integrating the grid with a unified power flow controller (UPFC) might stop the relay from fault-triggered operations, requiring altered relay characteristics. Building relay tripping parameters are among the critical challenges that must be addressed for transmission line distance relays because current transmission networks face higher stress regarding power system operation. Furthermore, the use of flexible AC transmission systems (FACTS) instruments at the transmission level adversely affects distance relay performance due to impedance differences. The UPFC is among the essential FACTS instruments; it comprises shunt and series converters to alter the apparent relay impedance; hence, it was considered for this study, where a test system during fault was assessed to demonstrate the output of the distance relay before and after using the UPFC. MATLAB was used to build scenarios demonstrating the effect of a UPFC located in the transmission line's midsection or end or not using the UPFC. This research offers an analytical technique to determine the probable effects of UPFC on distance relay characteristics. The outcomes provide new relay characteristics for several fault resistances and locations for fault-specific impedance trajectory reactions.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">University of Mosul, College of Engineering, Electrical Eng. Dept</dc:contributor>
	<dc:date>2023-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22492</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v14.i3.pp1577-1588</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 3: September 2023; 1577-1588</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v14.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22492/14274</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Hiba Nadhim A. Al-Kaoaz, Ahmed Nasser B. Alsammak</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>