Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Performance analysis of a robust MF-PTC strategy for induction motor drive

International Journal of Power Electronics and Drive Systems · Vol. 15 No. 1 (2024) · hlm. 251–260

DOI
10.11591/ijpeds.v15.i1.pp251-260
ISSN
2722-256X, 2088-8694
Terbit
2024-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The load model-based conventional predictive torque control (PTC) strategy performs as a high-performance controller at transient and steady-state conditions. However, its performance is poor on the issue of parameters variation. A robust model-free PTC (MF-PTC) strategy has been proposed in this paper to overcome the aforementioned drawback. An auto-regressive exogenous (ARX) model instead of a load model has been used to establish a model-free controller. This model is usually formed based on their input-output transfer function. A recursive least square algorithm has been employed to estimate the unknown parameters of the ARX model. Then, an observable canonical state-space model uses those estimated parameters to achieve an accurate prediction of the control variables. The performance of the proposed scheme can be affected by the variation of resistance. A resistance estimator based on the model reference adaptive system observer has been applied to improve the robustness of the system against variation of the stator and rotor resistance, and inductance measurement uncertainty. Simulation results show that the proposed MF-PTC scheme is robust against parameters uncertainty and works well at transient and steady-state conditions.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Khulna University of Engineering and Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Performance analysis of a robust MF-PTC strategy for induction motor drive</dc:title>
	<dc:creator>Hossen, Md. Belal</dc:creator>
	<dc:creator>Habibullah, Md.</dc:creator>
	<dc:subject xml:lang="en-US">auto-regressive exogenous model; induction motor; model reference adaptive system observer; model-free predictive torque control strategy; recursive least square algorithm</dc:subject>
	<dc:description xml:lang="en-US">The load model-based conventional predictive torque control (PTC) strategy performs as a high-performance controller at transient and steady-state conditions. However, its performance is poor on the issue of parameters variation. A robust model-free PTC (MF-PTC) strategy has been proposed in this paper to overcome the aforementioned drawback. An auto-regressive exogenous (ARX) model instead of a load model has been used to establish a model-free controller. This model is usually formed based on their input-output transfer function. A recursive least square algorithm has been employed to estimate the unknown parameters of the ARX model. Then, an observable canonical state-space model uses those estimated parameters to achieve an accurate prediction of the control variables. The performance of the proposed scheme can be affected by the variation of resistance. A resistance estimator based on the model reference adaptive system observer has been applied to improve the robustness of the system against variation of the stator and rotor resistance, and inductance measurement uncertainty. Simulation results show that the proposed MF-PTC scheme is robust against parameters uncertainty and works well at transient and steady-state conditions.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Khulna University of Engineering &amp; Technology</dc:contributor>
	<dc:date>2024-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22735</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v15.i1.pp251-260</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 15, No 1: March 2024; 251-260</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v15.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22735/14421</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Md. Belal Hossen</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>