Microbial Air Contamination in an Intensive Care Unit

International Journal of Public Health Science · Vol. 4 No. 3 (2015) · hlm. 145–151

DOI
10.11591/ijphs.v4i3.4725
ISSN
2620-4126, 2252-8806
Terbit
2015-09-01
Penerbit
Intelektual Pustaka Media Utama
Bahasa
eng

Abstrak

Unit layout affects every aspect of intensive care services, including patient safety. A previous study has shown that patients admitted to beds adjacent to the sink and to the door of a large bayroom had the highest number of positive blood cultures and the highest blood culture incidence density, respectively. The present study measures microbial air contamination in a medical intensive care unit of a medical center in central Taiwan. Of the 17 rooms, 8 rooms with distinct physical environmental characteristics were selected. Sampling tests were conducted between December 2013 and February 2014 with a microbial air sampler (MAS-100NT). TSA was used for bacteria collection and DG18 for fungi collection. The overall average bacterial and fungal concentrations were 83CFU/m3 and 69CFU/m3, respectively. The ranges were between 8-354 CFU/m3 and 0-1468 CFU/m3, respectively. A significant difference was found in the bacterial concentration (p=.005) between different room locations. The highest concentration was found in the rooms located at the front end of the circulation (99 CFU/m3), while the lowest was found in the rooms located at the rear end of the circulation (55CFU/m3). Differences in fungal concentrations for different room locations did not reach statistical significance. In addition, differences in bacterial and fungal concentrations for rooms with different sink locations did not reach statistical significance. Even though the microbial concentrations generally complied with standards, the results may help designers and hospital administrators develop a healthier environment for patients.

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Feng Chia University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijphs.iaescore.com/index.php/IJPHS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Microbial Air Contamination in an Intensive Care Unit</dc:title>
	<dc:creator>Chang, Chih-Yi</dc:creator>
	<dc:creator>Tseng, Liang</dc:creator>
	<dc:creator>Yang, Lung-Shih</dc:creator>
	<dc:description xml:lang="en-US">Unit layout affects every aspect of intensive care services, including patient safety. A previous study has shown that patients admitted to beds adjacent to the sink and to the door of a large bayroom had the highest number of positive blood cultures and the highest blood culture incidence density, respectively. The present study measures microbial air contamination in a medical intensive care unit of a medical center in central Taiwan. Of the 17 rooms, 8 rooms with distinct physical environmental characteristics were selected. Sampling tests were conducted between December 2013 and February 2014 with a microbial air sampler (MAS-100NT). TSA was used for bacteria collection and DG18 for fungi collection. The overall average bacterial and fungal concentrations were 83CFU/m3 and 69CFU/m3, respectively. The ranges were between 8-354 CFU/m3 and 0-1468 CFU/m3, respectively. A significant difference was found in the bacterial concentration (p=.005) between different room locations. The highest concentration was found in the rooms located at the front end of the circulation (99 CFU/m3), while the lowest was found in the rooms located at the rear end of the circulation (55CFU/m3). Differences in fungal concentrations for different room locations did not reach statistical significance. In addition, differences in bacterial and fungal concentrations for rooms with different sink locations did not reach statistical significance. Even though the microbial concentrations generally complied with standards, the results may help designers and hospital administrators develop a healthier environment for patients.</dc:description>
	<dc:publisher xml:lang="en-US">Intelektual Pustaka Media Utama</dc:publisher>
	<dc:date>2015-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijphs.iaescore.com/index.php/IJPHS/article/view/4725</dc:identifier>
	<dc:identifier>10.11591/ijphs.v4i3.4725</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Public Health Science (IJPHS); Vol 4, No 3: September 2015; 145-151</dc:source>
	<dc:source>2620-4126</dc:source>
	<dc:source>2252-8806</dc:source>
	<dc:source>10.11591/ijphs.v4i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijphs.iaescore.com/index.php/IJPHS/article/view/4725/3749</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2016 International Journal of Public Health Science (IJPHS)</dc:rights>
</oai_dc:dc>